过热器
护盾
锅炉(水暖)
屋顶
覆盖
环境科学
核工程
材料科学
冶金
管(容器)
结构工程
工程类
废物管理
复合材料
电磁屏蔽
程序设计语言
计算机科学
作者
María Asunción Valiente Bermejo,L. Magniez,Anna Jonasson,S. Selin,M. Frodigh,Kjell Hurtig,L-E. Stridh,Leif Karlsson
标识
DOI:10.1007/s11668-022-01337-5
摘要
Abstract Two experimental FeCrAl alloy overlay welds on tube shields were exposed in the superheater of a full-size waste fired boiler for 6 months. The tube shields were in different tube lines and positions within the superheater chamber to investigate possible heterogeneities in the exposure environment. The visual inspection of the exposed tube shields and the corrosion-erosion rates calculated from the analysis of cross-sections showed that the mid-length roof location experienced the most aggressive environment. The compositional differences between the two experimental alloys were not found to be determinant in their performance under these specific exposure conditions. It was concluded that erosion had a decisive influence on the results. The identification of local differences within the superheater chamber is important when deciding on the material selection for the different areas and locations to be protected. The output of this study is therefore interesting for further design consideration of superheaters as well as for future planning of exposures.