Evaluation of the accuracy, precision, and agreement of a glucometer compared to the standard laboratory test in diabetic and non-diabetic patients

医学 一致性 一致相关系数 平淡——奥特曼情节 科恩卡帕 变异系数 血糖性 血糖监测 罗氏诊断公司 标杆管理 相关系数 医学物理学 准确度和精密度 金标准(测试) 糖尿病 诊断准确性 卡帕 急诊医学 实验室试验 考试(生物学)
作者
Hamid Sharif Nia,Hosein Mokhtari,Jason W. Osborne,Shahriar Shafaei,Maryam Soltanzade,Hamid Sharif Nia,Hosein Mokhtari,Jason W. Osborne,Shahriar Shafaei,Maryam Soltanzade
出处
期刊:Scientific Reports [Nature Portfolio]
标识
DOI:10.1038/s41598-025-28009-2
摘要

Blood glucose monitoring is vital for diabetes management, with nurses playing a key role in glycemic monitoring and patient education. Despite their widespread use, the precision, accuracy and agreement of fingerprick glucometers with laboratory standards remain a significant concern. Discrepancies arise from multiple sources such as differences in sample type (whole blood vs. serum) and enzymatic technologies, potentially leading to clinical errors. Current international standards like ISO 15,197 have been insufficient in ensuring reliable device performance. Therefore, we need more rigorous benchmarking standards to assess their safety and reliability. This study aimed to evaluate the analytical and clinical accuracy, precision, and agreement of the glucosureSTAR point-of-care (POCT) glucometer against the standard laboratory method in diabetic and non-diabetic patients, following the ISO 15197:2013 standards. A cross-sectional study was conducted on 589 participants (136 diabetic and 453 non-diabetic). Paired blood glucose measurements were taken using the glucosureSTAR glucometer (glucose oxidase method) and a Roche Hitachi 917 laboratory analyzer. Analytical accuracy was assessed against ISO 15197:2013 criteria (± 15 mg/dL for values < 100 mg/dL, ± 15% for values ≥ 100 mg/dL). Clinical accuracy was evaluated using Parkes and Clarke Error Grid Analyses. Agreement was statistically analyzed using Bland-Altman plots, Passing-Bablok regression, and the Concordance Correlation Coefficient (CCC). Precision was tested via the coefficient of variation from 20 repeated measurements on three samples. Diagnostic performance was assessed using ROC curve analysis. The analytical accuracy of the glucometer marginally met the ISO 15197:2013 criteria (95.1% of results within ± 15 mg/dL or ± 15%). While clinical accuracy was acceptable (100% of points in Parkes error grid zones A/B), significant systematic error was observed. The device consistently underestimated blood glucose (mean bias: -3.3 mg/dL; 95% LoA: -38.7 to 32.1 mg/dL) with poor absolute agreement (CCC = 0.886). Precision failed ISO requirements at medium and high concentrations. ROC analysis revealed suboptimal diagnostic performance for detecting diabetes (AUC = 0.816; sensitivity = 62.18%, specificity = 93.26% at > 124 mg/dL cut-off). In conclusion, while the glucosureSTAR glucometer demonstrated acceptable clinical risk assessment with 100% of readings in clinically acceptable error grid zones, it showed significant limitations in analytical performance. The device exhibited systematic underestimation, wide variability, and failed to meet precision requirements at medium and high glucose concentrations. With 95.1% of the data points falling within the acceptable range by ISO15197:2013, and suboptimal diagnostic accuracy (sensitivity: 62.18%), this device should not be considered suitable for diagnostic purposes or therapy adjustment. It may be used with caution for trend monitoring in known diabetic patients where rapid results are prioritized over absolute accuracy but cannot replace standard laboratory methods when precise measurement is critical.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
刚刚
Xuech发布了新的文献求助10
刚刚
zhangpeiguo完成签到,获得积分10
刚刚
顾矜的应助被fanghaoxiang采纳,获得10
刚刚
kanghuihui发布了新的文献求助10
刚刚
今后的应助被包钰韬采纳,获得10
1秒前
1秒前
1秒前
闲01发布了新的文献求助10
2秒前
小刘发布了新的文献求助10
2秒前
momo发布了新的文献求助10
3秒前
调皮蓝血完成签到,获得积分10
3秒前
斯文败类的应助被怪怪采纳,获得10
3秒前
852的应助被科研狗-加班族采纳,获得10
3秒前
wxy发布了新的文献求助10
3秒前
邶莳完成签到,获得积分10
3秒前
3秒前
3秒前
钱途光明发布了新的文献求助10
4秒前
领导范儿的应助被qingshui采纳,获得10
4秒前
4秒前
Mahc完成签到,获得积分10
4秒前
英俊思真完成签到,获得积分10
4秒前
123完成签到 ,获得积分10
4秒前
半岛铁盒发布了新的文献求助10
5秒前
5秒前
Sn2026121172发布了新的文献求助10
6秒前
6秒前
重要的炳完成签到 ,获得积分10
6秒前
7秒前
7秒前
7秒前
民科大神qin完成签到,获得积分10
7秒前
完美世界的应助被cjf采纳,获得10
7秒前
李健的小迷弟的应助被七七采纳,获得10
7秒前
巧可脆脆发布了新的文献求助10
7秒前
8秒前
刘子田发布了新的文献求助10
9秒前
熊猫完成签到 ,获得积分20
9秒前
炙热梦曼发布了新的文献求助10
9秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Das Matthäusevangelium: Kapitel 1:1–17 1000
IRTSD: Open-Source Data and Toolset for Electromagnetic Transient Analysis of Disturbances and IBR Control Malfunctions in Transmission Systems 1000
Comprehensive Medicinal Chemistry IV (4th Edition) 800
Entre Praga y Madrid : los contactos checoslovaco-españoles (1948-1977) 600
A REVIEW OF THE V-22 DYNAMICS VALIDATION PROGRAM 600
Les Mots du discours 600
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 计算机科学 工程类 有机化学 化学工程 生物化学 物理 复合材料 内科学 催化作用 光电子学 人工智能 细胞生物学 无机化学 物理化学 数学
热门帖子
关注 科研通微信公众号,转发送积分 8121519
求助须知:如何正确求助?哪些是违规求助? 9526005
关于积分的说明 21558971
捐赠科研通 7700465
什么是DOI,文献DOI怎么找? 3415375
关于科研通互助平台的介绍 2541126
邀请新用户注册赠送积分活动 2455729