The optimization of low-dose scanning protocols of 64-slice spiral CT in the adult chest: a multicenter study

医学 核医学 图像噪声 图像质量 辐射剂量 曼惠特尼U检验 自动曝光控制 螺旋(铁路) 扫描仪 卡帕 内科学 图像(数学) 语言学 计算机科学 光学 物理 数学分析 哲学 人工智能 数学
作者
Wei Tang,Yao Huang,Ning Wu,Qiang Cai,Jianwei Wang,Suping Zhao
出处
期刊:Chinese journal of radiology 卷期号:45 (02): 142-148 被引量:1
标识
DOI:10.3760/cma.j.issn.1005-1201.2011.02.011
摘要

Objective To compare the image quality of chest low dose CT (LDCT) using automatic exposure control (AEC) and constant current control (CCC) and explore a more reasonable scanning protocol. Methods Two hundred and eighty participants were examined with 64 CT scanner at 7 centers in China. All were divided into 4 groups. Two groups underwent LDCT using AEC with standard deviation set at 25 (A1) and 30 (A2) respectively and the tube current ranged from 10 mA to 80 mA. The other two groups underwent LDCT using CCC with tube current set at 40 mA (C1) and 50 mA (C2) respectively. The axial and MPR images were evaluated by two radiologists who were blinded to the scanning protocols.The radiation dose, noise and the image quality of the 4 groups were compared and analyzed statistically.Differences of radiation dose and noise among groups were determined with variance analysis and t test,image quality with Mann-Whitney test and the consistency of diagnosis with Kappa test. Results There was a significant lower DLP in AEC group than in CCC group [(82.62±40.31)vs ( 110.81±18.21) mGy·cm (F =56. 88 ,P < 0. 01 )], whereas no significant difference was observed between group A2 and group A1 0. 05]. The noisy of AEC group was higher than that of CCC group both on lung window(41.50±9.58 vs 40.86±7.03) and mediastinum window (41.19±7.83 vs 40.92±9.89), but there was no significant difference( Flung =0.835, P=0.476, Fmediastinum =1.910, P=0.128).The quality score of axial image in AEC group was higher than that in CCC group (superior margin of the brachiocephalic vein level: 4.49±0.56 vs4.38±0.64,superior margin of the aortic arch: 4.86±0.23 vs 4.81±0.32,the right superior lobar bronchus Level:4.87±0.27 vs 4. 84 ± 0. 22, the right middle lobar bronchus Level: 4.90±0.25 vs 4.88±0.21) except on the right inferior pulmonary vein level(4. 92 ±0. 25 vs 4. 93 ±0. 17) and superior margin of the left diaphragmatic dome level (4. 91±0.27 vs 4.93±0.22) on lung window, but no significant differences (F=0.076-1.748, P>0.05) were observed. A significant higher score in AEC group was observed on mediastinum window compared with CCC group on superior margin of brachiocephalic vein level (2.57±0.77 vs 2. 46 ± 0. 59, F = 8. 459, P < 0. 05 ), however, the score of AEC group was lower than that of CCC group on other levels without significant differences (superior margin of the aortic arch:3.36 ±0. 63 vs 3.45 ±0. 60,the right superior lobar bronchus level: 3.94 ±0. 56 vs 3. 95 ±0. 51 ,the right middle lobar bronchus Level: 3.80 ±0. 58 vs 3. 87 ±0. 50,the right inferior pulmonary vein level: 3.72 ±0. 56 vs 3.78 ±0. 53, superior margin of the left diaphragmatic dome level: 3.58 ± 0.63 vs 3.68±0.56,F=0.083-3.380,P > 0.05 ). The MPR image quality of AEC group was better than that of CCC group both on lung window and mediastinum window (Zlung =-2.258, Zmedlastinum=-1.330, P>0.05). For all participants including the underweighted group, the normal group and the overweighted group, the image quality of A1 group was better than that of A2 group without significant differences (the underweighted group: Zlung=0.000, P=1.000, Zmedastinum= 0.000, P=1.000;the normal group: Zlung =-0.062, P=0.950, Zmediastinum =-0.746, P = 0.456; the overweighted group: Zlung = - 1.177, P = 0.239,Zmediastinum =-1.715, P=0.144) both on lung and mediastinum windows, and for the higher BMI participants, a better image quality was obtained in A1 group than in A2 group on the mediastinum window (Z = -1. 715, P = 0. 144). Conclusions The total radiation exposure dose of AEC group is significantly lower than that of CCC group, but no statistical significant differences are observed between both groups in image quality and noise level. The AEC technique is highly recommended in thoracic LDCT scan for screening program, and the SD25 ( SD value = 25) scan protocol is suggested for higher BMI population while the SD30 (SD value = 30) scan protocol for lower BMI population. Key words: Thorax;  Tomography, X-ray computed;  Diagnostic techniques and procedures; Radiation dosage

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
cccc发布了新的文献求助10
2秒前
4秒前
思维隋完成签到 ,获得积分10
4秒前
Akim应助小伙子很不错采纳,获得10
5秒前
5秒前
6秒前
羽梨发布了新的文献求助10
8秒前
lilili发布了新的文献求助10
8秒前
Young驳回了情怀应助
9秒前
沈霸霸发布了新的文献求助10
12秒前
wmz发布了新的文献求助10
14秒前
朱小朱完成签到 ,获得积分10
14秒前
17秒前
11111112222完成签到,获得积分10
20秒前
奥真奈美77完成签到,获得积分10
22秒前
23秒前
cccc完成签到,获得积分10
24秒前
wmz完成签到,获得积分10
24秒前
科目三应助hahhh7采纳,获得10
24秒前
小二郎应助羽梨采纳,获得10
24秒前
上官若男应助忆塔基采纳,获得10
25秒前
打打应助布丁采纳,获得30
28秒前
manman完成签到,获得积分10
29秒前
29秒前
大红马发布了新的文献求助30
29秒前
小二郎应助水博士采纳,获得10
32秒前
33秒前
34秒前
斯文败类应助博修采纳,获得10
34秒前
在水一方应助大红马采纳,获得10
35秒前
魏魏发布了新的文献求助10
37秒前
hahhh7发布了新的文献求助10
38秒前
42秒前
大红马完成签到,获得积分20
44秒前
彭于晏应助稳重的夏云采纳,获得10
44秒前
廖廖发布了新的文献求助10
46秒前
水博士发布了新的文献求助10
47秒前
Lucas应助shadow采纳,获得10
48秒前
Mtoc完成签到 ,获得积分10
48秒前
lilili完成签到,获得积分10
49秒前
高分求助中
(禁止应助)【重要!!请各位详细阅读】【科研通的精品贴汇总】 10000
Robot-supported joining of reinforcement textiles with one-sided sewing heads 800
水稻光合CO2浓缩机制的创建及其作用研究 500
Logical form: From GB to Minimalism 500
2025-2030年中国消毒剂行业市场分析及发展前景预测报告 500
The Netter Collection of Medical Illustrations: Digestive System, Volume 9, Part III – Liver, Biliary Tract, and Pancreas, 3rd Edition 400
Elliptical Fiber Waveguides 400
热门求助领域 (近24小时)
化学 材料科学 医学 生物 工程类 有机化学 生物化学 物理 内科学 纳米技术 计算机科学 化学工程 复合材料 遗传学 基因 物理化学 催化作用 冶金 细胞生物学 免疫学
热门帖子
关注 科研通微信公众号,转发送积分 4171129
求助须知:如何正确求助?哪些是违规求助? 3706599
关于积分的说明 11695134
捐赠科研通 3392446
什么是DOI,文献DOI怎么找? 1860702
邀请新用户注册赠送积分活动 920531
科研通“疑难数据库(出版商)”最低求助积分说明 832740