预制混凝土
焊接
结构工程
法律工程学
材料科学
复合材料
岩土工程
工程类
作者
Uğur Ersoy,Tuğrul Tankut
出处
期刊:Pci Journal
[Precast/Prestressed Concrete Institute]
日期:1993-07-01
卷期号:38 (4): 94-100
被引量:81
标识
DOI:10.15554/pcij.07011993.94.100
摘要
94 Precast concrete beams with dry joints, designed for multistory buildings located in a seismic area, were tested under reversed cyclic loading. In the original design, the connection was intended to transfer both shear and moment. It consisted of two steel plates, one at the top, the other at the bottom, welded to the anchored steel plates in the column bracket and the beam. The design was later revised by adding side plates. Five specimens with such connections and two monolithic reference specimens were tested under reversed cyclic loading to study their behavior under seismic action. The main variables were the presence of side plates and the joint width. Based on the test results, it is concluded that side plates are essential for dry joints which are expected to be subjected to seismic action. It is also concluded that for such connections, joint width is an important parameter and, therefore, tolerances should be checked carefully during erection.
科研通智能强力驱动
Strongly Powered by AbleSci AI