色谱法
废水
检出限
再现性
化学
萃取(化学)
高效液相色谱法
基质(化学分析)
洗脱
决定系数
固相萃取
液相色谱-质谱法
环境科学
污水处理
墨盒
分析化学(期刊)
恩诺沙星
过滤(数学)
作者
OMPRAKASH UNIYAL,SANJEEV K SAHU
标识
DOI:10.22159/ajpcr.2026v19i9.60264
摘要
Objectives: The present study aimed to develop and validate a green and stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous determination of metronidazole, ornidazole, ofloxacin, chloramphenicol, and moxifloxacin hydrochloride in hospital wastewater samples collected from Dehradun, Uttarakhand. Methods: Chromatographic separation was achieved using an Accellis C18 column (150 × 4.6 mm, 5 μm) with gradient elution employing buffer (pH 2.5±0.05) and acetonitrile as mobile phase at a flow rate of 1.0 mL/min with ultraviolet-photodiode array detector detection at 280 nm. Wastewater samples were subjected to membrane filtration followed by solid-phase extraction before analysis. The developed RP-HPLC method was validated according to International Council for Harmonization Q2(R1) guidelines. Environmental sustainability was evaluated using analytical GREEnness metric approach, green analytical procedure index, blue applicability grade index, analytical method greenness score, and high-performance liquid chromatography environmental assessment tool assessment tools. Results: The developed RP-HPLC method demonstrated satisfactory specificity, precision, and linearity for all investigated antibiotics. System suitability results showed percentage relative standard deviation values below 1.1%, tailing factors between 1.012 and 1.125, and theoretical plate counts above 3400. Excellent linearity was obtained with regression coefficient (R2) values ranging from 0.999980 to 1.000000. Limit of detection and limit of quantification values ranged between 0.041 and 0.095 μg/mL and 0.124–0.286 μg/mL, respectively. Recovery values ranged from 95.60% to 103.10%, while matrix effect values remained within ±5%. Forced degradation studies confirmed the stability-indicating capability of the developed method. Antibiotic residues were detected in wastewater samples at concentrations ranging from 0.88 to 3.95 μg/L. Process capability analysis demonstrated acceptable analytical reproducibility with capability values >1.33. Sustainability assessment confirmed acceptable environmental performance of the developed analytical procedure. Conclusion: The validated RP-HPLC method was found to be sensitive, robust, environmentally acceptable, and suitable for routine monitoring of antibiotic residues in hospital wastewater samples.
科研通智能强力驱动
Strongly Powered by AbleSci AI