The forced convective heat transfer data are generally correlated as a function of flow rate, physical properties of fluid and geometry of the system. The proposed equations are generally complex, as revealed by literature. However, heat transfer coefficient data can be predicted from a single simple equation for a variety of geometries. This method helps in reducing the time and cost of experimental investigations. The forced convective heat transfer coefficient data obtained with full length twisted-tape inserts used for flow of air are well-correlated as Nu = 2.34 (Remod)0.2448. In this equation Nu is Nusselt number and Remod is modified Reynolds number. It is to be noted that this equation is without the aid of Prandtl number and the tape twist ratio. This study confirms that a simplified method is possible for correlating the forced convective heat transfer data without the aid of Prandtl number and the additional geometrical parameters of the system.