多塔
前列腺癌
医学
正电子发射断层摄影术
谷氨酸羧肽酶Ⅱ
活检
核医学
靶病变
PET-CT
放射科
癌症
内科学
体内
生物技术
心肌梗塞
经皮冠状动脉介入治疗
生物
作者
Jingfeng Zhang,Shaoxi Niu,Yachao Liu,Xiaojun Zhang,Xiaohui Luan,Huanhuan Liu,Yue Pan,Xiaodan Xu,Shina Wu,Yuan Wang,Zhiqiang Chen,Baojun Wang,Xu Zhang,Ruimin Wang,Jinming Zhang,Yachao Liu
标识
DOI:10.1007/s00259-024-07000-5
摘要
Prostate-specific membrane antigen positron emission tomography (PSMA-PET) guided targeted biopsy has shown potential for detecting more prostate cancer (PCa) cases. However, relying exclusively on imaging may risk missing lesions, an issue that could be addressed by incorporating radiation-guided technology. Accordingly, we aimed to develop a novel PSMA radiotracer with a long half-life, [64Cu]Cu-DOTA-PSMA-3Q, and evaluate its targeting accuracy. Additionally, this research explored the practicability of real-time lesion verification during surgical interventions. In this study, we synthesized the radiotracer [64Cu]Cu-DOTA-PSMA-3Q and verified its PSMA specificity and safety. We prospectively enrolled 18 patients with suspected PCa for PET/CT imaging to assess the efficacy of PCa detection; 10 patients underwent targeted biopsy combined with standard template biopsy at an interval of 24 h after injection. The radioactivity of the biopsy tissue was quantified in counts per minute (CPM) using a gamma spectrometer intraoperatively. The efficacy and specificity of [64Cu]Cu-DOTA-PSMA-3Q were confirmed through preclinical cell and animal studies. In clinical settings, PET/CT imaging performed 2 h after injection visualized all of the PSMA-positive lesions both within and outside the prostate. The assessment of human organ radiation exposure indicated that the kidneys received the highest absorbed dose, followed by the bladder wall, salivary glands, and liver. In 10 patients, a total of 132 biopsy cores were extracted, with 53 cores histologically confirmed as PCa. The median CPM for PCa tissues was significantly greater at 134,148 CPM compared to 18,39 CPM for normal prostate tissues (P < 0.001). Receiver operating characteristic (ROC) curve analysis yielded an AUC of 0.8837, suggesting high diagnostic accuracy. The optimal diagnostic cut-off was established at 66 CPM, achieving a sensitivity of 77.36%. Radiation-guided technology using [64Cu]Cu-DOTA-PSMA-3Q improves the reliability of PSMA-PET image-guided biopsy, enables instant confirmation of sample lesions during surgical procedures, and holds potential for achieving optimized puncture outcomes. Chinese Clinical Trial Registry ChiCTR2300072655, Registered 20 June 2023.
科研通智能强力驱动
Strongly Powered by AbleSci AI