All-solid-state battery (ASSB) are expected to be a solution to increase energy density in Li-ion technology. However, high-energy storage capacities make the safety a crucial issue. The main reactions leading to thermal runaway in conventional LiB are anode/electrolyte at 110 °C, electrolyte decomposition at 150 °C and cathode/electrolyte at 300 °C. Therefore, without liquid electrolyte, it can be expected that ASSB are less likely to have a thermal runaway. To assess safety of such non-fully mature battery technologies, a new methodology is proposed and a closed calorimeter was designed to perform operando experiments in abuse conditions with high-speed synchrotron X-ray radiography and measurement of temperature, pressure and energy. The data and image of thermal runaway of all-solid-state batteries are presented and compared to the result of Li-ion batteries with liquid electrolyte. An 11 % decrease of heat release was measured for cell with solid electrolyte. Gas volume, amount of matter that reacts in the cell and reaction kinetics have also been compared. Such a methodology allows deepening hypotheses on associated material degradation and that can assist in development of new battery technologies, by evaluating battery safety from the start of the design from battery composition to cell shape.