结垢
膜污染
过滤(数学)
化学
膜
膜式过滤器
滤波器(信号处理)
滤饼过滤器
色谱法
化学工程
粘度
细菌外膜
错流过滤
压缩系数
杀生物剂
膜技术
环境工程
制浆造纸工业
曝气
反冲洗
小泡
作者
Angela Esposito,Guido Borgianni,Marco Cardinali,Domenico Colucci,Francesco Carpitella,Andrea Albano
标识
DOI:10.1016/j.memsci.2026.126431
摘要
Frontal filtration is a critical step in the manufacture of sterile drug products (DPs), ensuring bioburden control and product sterility. Robust filtration process development is particularly important for challenging products such as bacterial Outer Membrane Vesicles (OMVs). Despite their widespread use in commercial vaccines, the fouling mechanisms associated with OMV sterile filtration have not, to our knowledge, been systematically investigated. The objective of this study was to identify the most appropriate fouling model for OMV filtration and evaluate the impact of operating conditions on filter capacity ( ). Among the classical fouling models, the Complete Blocking model provided the best description of OMV fouling during constant-transmembrane-pressure (TMP) filtration and enabled accurate prediction of Sartopore Platinum filter capacity. Selection of an inappropriate fouling model resulted in filter-capacity overpredictions of up to 240%, highlighting the importance of mechanistic model selection during process development. The effects of temperature and TMP on Vmax were investigated. Contrary to the behavior reported for mRNA-LNPs and liposomes, OMV filter capacity increased as TMP decreased. Filter capacity varied from approximately 31 L m -2 (5 °C, 150 kPa) to more than 150 L m -2 (≥ 17.8 °C, 50 kPa) across the operating conditions investigated. The observed pressure dependence is consistent with the hypothesis that lipopolysaccharides (LPS) and outer membrane proteins (OMPs) may increase OMV rigidity and reduce particle compressibility relative to other lipid-based nanoparticles. In addition, lower temperatures were associated with increased fouling rates and reduced filter capacity, an effect that could not be explained by the temperature dependence of the feed viscosity alone. Finally, a predictive model describing the fouling constant ( ) as a function of TMP and temperature was developed and successfully verified against independent experimental data (R 2 = 0.92). These findings highlight the importance of correctly identifying the dominant fouling mechanism to accurately predict filter capacity and support robust process development for OMV-based vaccine products.
科研通智能强力驱动
Strongly Powered by AbleSci AI