医学
钆酸
磁共振成像
工件(错误)
核医学
稀释
二乙烯三胺五乙酸
威尔科克森符号秩检验
生理盐水
曼惠特尼U检验
放射科
麻醉
钆DTPA
内科学
螯合作用
化学
物理
有机化学
神经科学
生物
热力学
作者
Young Kon Kim,Wei‐Chan Lin,Kyunghyun Sung,Steven S. Raman,Daniel Margolis,Yaeji Lim,Seonhye Gu,David Lu
出处
期刊:Radiology
[Radiological Society of North America]
日期:2016-12-15
卷期号:283 (2): 429-437
被引量:41
标识
DOI:10.1148/radiol.2016160241
摘要
Purpose To compare two contrast material-administration protocols (dilution vs slow injection) in terms of their effectiveness in arterial phase artifact reduction at gadoxetic acid-enhanced magnetic resonance (MR) imaging. Materials and Methods This HIPAA-compliant retrospective case-controlled cohort study was approved by the institutional review board, with a waiver of informed patient consent. A total of 318 consecutive patients undergoing gadoxetic acid-enhanced MR imaging were placed into one of two subcohorts of 159 consecutive patients each: the dilution subcohort (gadoxetic acid was diluted 1:1 with saline and injected at a rate of 2.0 mL/sec) and the slow injection subcohort (gadoxetic acid was not diluted and was injected at a rate of 1.0 mL/sec). Eighty-nine patients in the dilution subcohort also underwent follow-up MR imaging with the slow injection method, and 34 patients in the slow injection subcohort underwent follow-up MR imaging with the dilution method. Both patient- and image-based analyses, as well as intraindividual analysis, were used to compare two parameters-mean artifact score rated by two observers using a five-point scale and frequency of severe artifact-between the dilution and slow injection subcohorts with the Wilcoxon Mann-Whitney test, χ2 test, and generalized estimating equation. Results In both patient- and image-based analyses, the mean artifact score and frequency of severe artifact were lower in the dilution subcohort (mean, 1.46% and 3.8% [six of 159]) than in the slow injection subcohort (mean, 1.95% and 15.1% [24 of 159]) (P ≤ .001 and P < .001, respectively). In intraindividual analysis, both variables were also decreased in the dilution subcohort (P = .007 and P = .001, respectively). We found the two variables to be significantly increased in the slow injection subcohort when compared with that in the dilution subcohort for three different MR platforms (P < .05). Conclusion In comparison with slow injection of undiluted contrast material at a rate of 1.0 mL/sec, gadoxetic acid diluted to 50% and injected at a rate of 2 mL/sec had a significantly less severe ghosting artifact in the arterial phase of gadoxetic acid-enhanced MR imaging. © RSNA, 2016 Online supplemental material is available for this article.
科研通智能强力驱动
Strongly Powered by AbleSci AI