Objective A retrospective study was carried out to analyze the indications of 18F-fluorodeoxyglucose (FDG) PET in differential diagnosis between benign and malignant lesions of lung. Methods The chest X ray plain film and CT scanning was first performed on 86 patients for suspected lung cancer. And then chest or whole body PET imaging was also performed and standard uptake value (SUV) were calculated. Results 7 latent malignant tumors were found by PET in 6 patients with pulmonary atelectasis and 4 patients with hydrothorax. 4 lung cancer nodules were also correctly detected by PET in 7 inflammatory and 7 tuberculous foci which were not markedly improved after standard treatment for 2~4 weeks. Thereby, the accuracy of 18F-FDG PET imaging among above groups were 100%, 85.7% and 71.4%, respectively. In 46 patients with suspected lung cancer but without typical radiological signs, the accuracy of PET was 89.1%, whereas 16 patients with typical radiological images were also correctly defined. Conclusion The pulmonary atelectasis or hydrothorax without mass image, inflammatory or tuberculous foci which were unchanged after standard treatment and atypical lung nodules in chest radiology are recommend to be as the indications of 18F-FDG PET imaging in differential diagnosis of lung cancer.