脱氢抗坏血酸
抗坏血酸
二硫苏糖醇
化学
色谱法
生物化学
食品科学
酶
作者
Sam A. Margolis,Robert C Paule,Regina G. Ziegler
出处
期刊:Clinical Chemistry
[American Association for Clinical Chemistry]
日期:1990-10-01
卷期号:36 (10): 1750-1755
被引量:68
标识
DOI:10.1093/clinchem/36.10.1750
摘要
We describe a rapid method for accurately and precisely measuring ascorbic acid and dehydroascorbic acid in plasma. Total analysis time is less than 10 min, replicate analyses of a single pool provide precision less than or equal to 2%, and values measured in supplemented samples agree with known concentrations of 4.68 and 11.83 mg/L. The stability and homogeneity of lyophilized plasma samples supplemented with ascorbic acid and dithiothreitol are documented. We also describe a procedure in which metaphosphoric acid (50 g/L) is used to prepare a reference material for the measurement of ascorbic acid and dehydroascorbic acid. The procedure for both acids consists of first measuring the native ascorbic acid, then reducing the dehydroascorbic acid, at neutral pH, with dithiothreitol, and finally measuring the total ascorbic acid; dehydroascorbic acid is then determined by difference. The metaphosphoric-acid-treated samples were stable at -70 degrees C, but stability decreased with temperature over the range examined, 4-50 degrees C.