离子
猝灭(荧光)
荧光
发光
水溶液
水溶液中的金属离子
材料科学
化学
分析化学(期刊)
金属有机骨架
检出限
光化学
无机化学
人类健康
水介质
荧光光谱法
作者
Shipeng He,G. R. WU,Lin Zhu,Dating Tian
标识
DOI:10.1002/slct.202506284
摘要
ABSTRACT Abnormal concentrations of Fe 3 + ions in aquatic environments can pose major health risks. Long‐term exposure to Fe 3+ ions may cause kidney damage and cardiovascular disease. Thus, reliable detection of Fe 3+ ions in water bodies is critical for environmental protection and human health. We used a low‐cost luminous hydrogen‐bonded organic framework (HOF‐MT) synthesized via a facile approach to detect Fe 3 + ions in aqueous solutions. The successful preparation of the HOF‐MT was confirmed by various characterization methods. We tested the fluorescence (FL) performance of HOF‐MT and found that Fe 3 + ions exhibited a sensitive FL quenching phenomenon toward HOF‐MT. The FL intensities of HOF‐MT showed a good linear correlation with Fe 3+ concentrations (15–75 mmol/L). We found that the sensing mechanism of HOF‐MT on Fe 3 + ions was a combination of dynamic quenching and internal filtering effect (IFE). Moreover, we successfully applied the HOF‐MT to detect Fe 3+ ions in real water samples, suggesting that this method is suitable for environmental detection.
科研通智能强力驱动
Strongly Powered by AbleSci AI