心室辅助装置
连续流动
心脏病学
内科学
重症监护医学
作者
Nicholas McNamara,Harry Narroway,Michael L. Williams,John Brookes,James Farag,David Cistulli,Paul G. Bannon,Silvana Marasco,Evgenij Potapov,Antonio Loforte
标识
DOI:10.21037/acs-2021-cfmcs-35
摘要
End stage heart failure is a major cause of morbidity and mortality, and its prevalence is expected to rise with the ageing population. For suitable patients, orthotopic heart transplantation remains the gold standard therapy, however, a paucity of donor organs has led to the development of left ventricular assist devices (LVAD). These devices can be utilized as either a bridge-to-transplant (BTT) or as an alternative to heart transplantation. While these devices can prolong life and improve quality of life, they are associated with a significant number of adverse events. We aim to systematically review the literature to quantify survival and the incidence of adverse events following implantation of continuous-flow LVADs (cf-LVAD).A systematic review was performed to determine outcomes following implantation of a cf-LVAD. Primary outcomes were survival and frequency of adverse events (such as bleeding, infection, thrombosis, stroke and right ventricular failure). Secondary outcomes included quality of life and assessment of functional status.Sixty-three studies reported clinical outcomes of 9,280 patients. Survival after cf-LVAD varied between studies. Industry-funded trials generally reported better overall survival than the single- and multi-center case series, which showed significant variation. The largest registry report documented twelve, twenty-four and forty-eight-month survival rates of 82%, 72% and 57% respectively. The most commonly reported adverse events were gastrointestinal bleeding (GIB), device-related infection, neurological events and right heart failure (RHF). Bleeding, RHF and infection were the most frequent complications experienced by those supported with cf-LVAD, occurring in up to 35%, 40% and 55% of patients, respectively. Quality of life as measured using the Kansas City Cardiomyopathy Questionnaire (KCCQ) and functional status as measured with the 6-minute walk test (6MWT) improved after cf-LVAD implantation with no decline evident two years after implantation.The paucity of donor hearts has led to the development of left-ventricular assist devices as a BTT or as a destination therapy (DT). Outcomes after cf-LVAD implantation are excellent, with short-term survival comparable to heart transplantation, but long-term survival remains limited due to the incidence of post-implantation adverse events. Despite these complications, quality of life and functional status improve significantly post-implantation and remain improved over the long-term. This study demonstrates the potential benefits of cf-LVAD therapy whilst also identifying adverse events as an area of increased morbidity and mortality.
科研通智能强力驱动
Strongly Powered by AbleSci AI