生物相容性
材料科学
微弧氧化
腐蚀
骨整合
钛
纳米技术
钛合金
冶金
生物医学工程
植入
合金
医学
外科
镁合金
作者
Xueying Wen,Yan Liu,Fangquan Xi,Xingwan Zhang,Yuanyuan Kang
标识
DOI:10.3389/fbioe.2023.1282590
摘要
Titanium (Ti) and its alloys have good biocompatibility, mechanical properties and corrosion resistance, making them attractive for biomedical applications. However, their biological inertness and lack of antimicrobial properties may compromise the success of implants. In this review, the potential of micro-arc oxidation (MAO) technology to create bioactive coatings on Ti implants is discussed. The review covers the following aspects: 1) different factors, such as electrolyte, voltage and current, affect the properties of MAO coatings; 2) MAO coatings affect biocompatibility, including cytocompatibility, hemocompatibility, angiogenic activity, corrosion resistance, osteogenic activity and osseointegration; 3) antibacterial properties can be achieved by adding copper (Cu), silver (Ag), zinc (Zn) and other elements to achieve antimicrobial properties; and 4) MAO can be combined with other physical and chemical techniques to enhance the performance of MAO coatings. It is concluded that MAO coatings offer new opportunities for improving the use of Ti and its alloys in biomedical applications, and some suggestions for future research are provided.
科研通智能强力驱动
Strongly Powered by AbleSci AI