医学
玻璃体切除术
卫生棉条
视力
外科
黄斑裂孔
内界膜
移植
眼科
耐火材料(行星科学)
天体生物学
物理
作者
Takaaki Yuguchi,Shuntaro Ogura,Yoshio Hirano,Norihiro Suzuki,Tsutomu Yasukawa,Yuichiro Ogura
出处
期刊:Retinal Cases & Brief Reports
[Ovid Technologies (Wolters Kluwer)]
日期:2023-03-01
卷期号:17 (2): 85-88
被引量:2
标识
DOI:10.1097/icb.0000000000001128
摘要
Purpose: To report a case of refractory macular hole (MH) in pseudophakic eye treated with autologous posterior capsule flaps transplantation. Methods: Case report. Results: A 48-year-old man visited our hospital with visual loss in the right eye because of unclosed MH. The patient had undergone two previous surgeries in another hospital, that is, the first included a cataract surgery, vitrectomy, and internal limiting membrane peeling with sulfur hexafluoride (SF 6 ) gas tamponade, and the second included an ineffective autologous internal limiting membrane flap technique and massaging the edges of the MH with a soft-tipped flute needle followed by the same gas, but the MH remained open. In our hospital, posterior capsule flaps were acquired from the same eye, inserted into the MH, and the same gas tamponade was performed, which was about four months after the disease onset (3 months after the prior second surgery). The patient kept face-down position for a week after the surgery and the MH was closed, which remained for over 12 months. The visual acuity improved from 20/250 to 20/60, and the retinal sensitivities around the MH gradually improved. Conclusion: An autologous posterior capsule flaps transplantation was effective in the management of refractory MH to not only close the MH but also improve the visual outcomes.