色谱法
化学
甲酸
药代动力学
选择性反应监测
质谱法
丝裂霉素C
液相色谱-质谱法
串联质谱法
萃取(化学)
高效液相色谱法
药理学
医学
外科
作者
Kyung-Sun Moon,Jong-Min Song,JiMin Yi,Quynh Khoa Pham,Sung‐Hoon Ahn
出处
期刊:Heliyon
[Elsevier BV]
日期:2024-06-01
卷期号:10 (12): e32927-e32927
标识
DOI:10.1016/j.heliyon.2024.e32927
摘要
To develop the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for measuring mitomycin C in rat plasma, samples were processed using solid-phase extraction, with the internal standard being carbamazepine. A reversed phased C18 column was utilized for the LC-MS/MS study, and mobile phases consisting of 0.1 % formic acid in acetonitrile and water were injected into it at a rate of 0.3 mL/min. Multiple reaction monitoring in positive-ion mode with precursor-product ion pairs 335.3 → 242.3 (mitomycin C) and 237.1 → 194.1 (carbamazepine) was employed to quantify the compounds. The linear range in plasma was found to be 10–4000 ng/mL (r2 = 0.992). The inter-batch and intra-batch precision were <14.3 % (LLOQ: 14.7 %) and 13.4 % (LLOQ: 16.1 %), respectively. The recovery and the matrix effect of mitomycin C in plasma were 113 % and 111 %, respectively. Mitomycin C was stable under the conditions of this assay method. In the end, this approach proved effective in a pharmacokinetic investigation with the intravenous and oral administration of mitomycin C to rats.