Comparison of Three Methods in Diagnosing Maxillary Transverse Discrepancy Thesis by Madison Smith, D.D.S. Introduction There are several different methods in determining the maxillary transverse discrepancy (MTD). In specific, MTD can be determined with the help of a cone beam computer tomography (CBCT), 3D scan and models, or simply a 2D occlusogram. Do they provide the same MTD values for diagnosing transverse discrepancies? A patient may need a certain amount of skeletal and dental expansion based on a diagnosis of MTD, but this amount may vary depending on the diagnosis method used. There is a lack of knowledge in the literature comparing 2D and 3D methods in determining MTD. Currently, methods in measuring MTD include but not limited to utilizing posteroanterior (PA) cephalograms, digital scans, dental casts, and cone-beam computed tomography (CBCT) radiographs. In the current study, three different methods will be compared (Yonsei analysis on CBCT, Dr. Tim Tremont’s method on digital models, and a method by WVU faculty Dr. Khaled Alsharif using bony landmarks on digital models). The purpose of this study is to determine the difference among these three methods and inform orthodontists what methods similarly diagnose MTD. Methods The transverse dimension was measured and diagnosed using three methods. These included CBCT according to the Yonsei analysis as well as two separate methods using the dental casts via digital models, the Tremont analysis and the unpublished method used by WVU faculty, Dr. Khaled Alsharif. Once the measurements were taken and the MTD was determined for each of the three methods, a statistical analysis was performed to evaluate if there were any statistically significant differences in MTD among the three methods. Inclusion criteria included de-identified orthodontic patients 10 years old or above, no prior orthodontic treatment, CBCT capturing both the maxilla and mandible, and a digital scan of maxilla and mandible. Exclusion criteria included prior orthodontic treatment and patients with craniofacial abnormalities such as cleft lip/palate. Results: We performed repeated measures ANOVA followed by Tukey honesty significant difference (HSD) test to determine the differences in MTD scores using 3 MTD diagnostic methods. There was significant difference in mean MTD scores between at least two MTD diagnostic methods (F (2, 54) = 5.50, p=0.007). The post-hoc HSD test results showed significant differences in mean MTD scores between Alsharif method (-3.24 ± 2.51) and Tremont method (-2.44 ± 2.66), and between Tremont (-2.44 ± 2.66) method and Yonsei method