Daewon Baek,Youngjong Ko
标识
DOI:10.1109/jestpe.2026.3739528
摘要
In three-level T-type inverters, open-circuit faults in outer switches pose a critical threat as they restrict current paths, leading to severe output current distortion and neutral-point (NP) voltage imbalance. Furthermore, the loss of connection to the DC-link capacitors severely limits the achievable linear modulation index (MI) range due to reduced DC-link voltage utilization. While hardware-based fault-tolerant control (FTC) methods require expensive and bulky auxiliary components, conventional hardware-free methods are severely limited to an MI of 1/√3. To overcome these limitations, this paper proposes an advanced hardware-free FTC specifically designed for standalone T-type inverter systems. By intentionally regulating the NP voltage imbalance through carrier-based PWM with selective two-level operation, the proposed method recovers the DC-link voltage utilization and extends the post-fault linear MI range. Crucially, the two-level modulation is applied only during specific intervals where three-level operation is physically unavailable, thereby preserving the low harmonic distortion and high efficiency of the three-level inverter. Simulation and experimental results verify that the proposed FTC maintains stable post-fault operation and extends the linear MI range without requiring additional hardware.