医学
心房颤动
剪裁(形态学)
心耳
血栓
闭塞
外科
冲程(发动机)
烧蚀
心脏病学
内科学
窦性心律
机械工程
工程类
语言学
哲学
作者
Adnan Ahmed,Naga Venkata K. Pothineni,Vinod K. Singh,Danish Bawa,Douglas Darden,Rajesh Kabra,Angad Singh,Saira Memon,ahmed romeya,Justin Van Meeteren,Senthil Thambidorai,Dhanunjaya Lakkireddy,Rakesh Gopinathannair
标识
DOI:10.1016/j.amjcard.2023.06.026
摘要
Surgical left atrial appendage (LAA) occlusion with an AtriClip (AtriCure, West Chester, Ohio) is frequently performed for stroke prophylaxis in patients with atrial fibrillation (AF). We conducted a retrospective analysis of all patients with long-standing persistent AF who underwent hybrid convergent ablation and LAA clipping. Contrast-enhanced cardiac computed tomography was performed at 3 to 6 months after LAA clipping to assess the degree of complete closure and the residual LAA stump. A total of 78 patients (64 ± 10 years, 72% male) underwent LAA clipping as part of hybrid convergent AF ablation, from 2019 to 2020. Median size of AtriClip used was 45 mm. Mean LA size was 4.6 ± 1 cm. At 3-to-6 months follow-up computed tomography, 46.2% of patients (n = 36) had a residual stump proximal to the deployed LAA clip. Mean depth of residual stump was 3.95 ± 5.5 mm, with 19% of patients (n = 15) having a stump depth of ≥10 mm and 1 patient requiring more endocardial LAA closure owing to large stump depth. During 1-year follow-up, 3 patients developed stroke; device leak of 6 mm was noted in 1 patient; and none of the patients had a thrombus proximal to the clip. In conclusion, high incidence of residual LAA stump was observed with AtriClip. Larger studies with long-term follow-up are needed to better assess the thromboembolic implications of a residual stump after AtriClip placement. Surgical left atrial appendage (LAA) occlusion with an AtriClip (AtriCure, West Chester, Ohio) is frequently performed for stroke prophylaxis in patients with atrial fibrillation (AF). We conducted a retrospective analysis of all patients with long-standing persistent AF who underwent hybrid convergent ablation and LAA clipping. Contrast-enhanced cardiac computed tomography was performed at 3 to 6 months after LAA clipping to assess the degree of complete closure and the residual LAA stump. A total of 78 patients (64 ± 10 years, 72% male) underwent LAA clipping as part of hybrid convergent AF ablation, from 2019 to 2020. Median size of AtriClip used was 45 mm. Mean LA size was 4.6 ± 1 cm. At 3-to-6 months follow-up computed tomography, 46.2% of patients (n = 36) had a residual stump proximal to the deployed LAA clip. Mean depth of residual stump was 3.95 ± 5.5 mm, with 19% of patients (n = 15) having a stump depth of ≥10 mm and 1 patient requiring more endocardial LAA closure owing to large stump depth. During 1-year follow-up, 3 patients developed stroke; device leak of 6 mm was noted in 1 patient; and none of the patients had a thrombus proximal to the clip. In conclusion, high incidence of residual LAA stump was observed with AtriClip. Larger studies with long-term follow-up are needed to better assess the thromboembolic implications of a residual stump after AtriClip placement.
科研通智能强力驱动
Strongly Powered by AbleSci AI