摘要
In Brief Study Design. A cadaveric specimen study. Objectives. To determine the applicability of a modified C2 translaminar screw placement in the general adult population and to provide pertinent clinical data for screw insertion. Summary of Background Data. C2 intralaminar screw fixation has recently been popularized, but this technique carries a potential drawback that the screw may breakout ventrally into the spinal canal. For this reason, a modified C2 translaminar screw fixation technique was developed to intraoperatively verify screw position and thereby decrease the risk or canal compromise. To our knowledge, there has been not an anatomic study evaluating this modification of the translaminar screw technique. Methods. The tips of the modified screws were aimed such that they exited the dorsal cortex of the center of the contralateral lateral mass, achieving bicortical fixation. A total of 120 adult C2 vertebrae were evaluated bilaterally for the following: thickness of the cranial, midportion, and caudal edge of C2 lamina; the heights of the spinous process, lamina, and lateral mass; inclination angle of the laminae, screw projection length, and trajectory angle of cranial and caudal C2 translaminar screw. Results. A total of 83.3% specimens had bilateral laminar thicknesses ≥4.0 mm and a spinous process height ≥9.0 mm; 5% had a laminar thickness less than 4.0-mm bilaterally; 9.2% had a laminar thickness less than 4.0 mm on one side; 2.5% had a spinous process height lower than 9.0 mm. Conclusion. A large percentages of C2 laminae are of sufficient size to safely accommodate a bicortical 3.5-mm diameter screw. The thickness of the lamina and the height of the spinous process are the 2 limiting factors for safe translaminar screws placement. Using a bicortical technique confirms the position of the screw and thereby helps to decrease the risk of neurologic injury from screw penetration of the inner cortex of the lamina. A modified C2 translaminar screw fixation technique using bicortical screw fixation was developed and 120 adult axis specimens were measured to evaluate the applicability of this technique. Lamina thickness and spinous process height are the 2 limiting factors, but large percentages of C2 specimens are of sufficient size to safely accommodate a bicortical translaminar screw.
科研通智能强力驱动
Strongly Powered by AbleSci AI