胃电图
鱿鱼
磁强计
波形
相关性
电极
生物医学工程
材料科学
医学
核磁共振
物理
内科学
生物
数学
胃
磁场
电压
几何学
量子力学
生态学
作者
Suseela Somarajan,Nicole D. Muszynski,Chibuike Obioha,William O. Richards,Leonard A. Bradshaw
标识
DOI:10.1088/0967-3334/33/7/1171
摘要
We measured gastric slow wave activity simultaneously with a Superconducting Quantum Interference Device (SQUID) magnetometer, mucosal electrodes and cutaneous electrodes in 18 normal human subjects (11 women and 7 men). We processed signals with Fourier spectral analysis and SOBI blind-source separation techniques. We observed a high waveform correlation between the mucosal electromyogram (EMG) and multichannel SQUID magnetogastrogram (MGG). There was a lower waveform correlation between the mucosal EMG and cutaneous electrogastrogram (EGG), but the correlation improved with the application of SOBI. There was also a high correlation between the frequency of the electrical activity recorded in the MGG and in mucosal electrodes (r = 0.97). We concluded that SQUID magnetometers noninvasively record gastric slow wave activity that is highly correlated with the activity recorded by invasive mucosal electrodes.