Experiment on co-firing of Vietnamese anthracite and Shanxi bituminous coal in a W-flame boiler was conducted,by pre-mix and late-mix ways.During combustion,the proportion of bituminous coal was gradually increased.The variation trends of slagging situation,combustible ash content,flame temperature and pulverizing system safety with different co-firing ways and mixed ratios were compared.The results showed that,the best anthracite/bituminous mass ratio was 4:6,and the pre-mix way was suggested.