通风(建筑)
服装
环境科学
工程类
机械工程
考古
历史
作者
Jie Yang,Faming Wang,Guowen Song,Rui Li,Uday Raj
出处
期刊:International Journal of Occupational Safety and Ergonomics
日期:2020-04-29
卷期号:28 (1): 354-363
被引量:50
标识
DOI:10.1080/10803548.2020.1762316
摘要
Effects of clothing size and air ventilation rate on the cooling performance of three air ventilation jackets (size small, medium and large) were investigated. Two ventilation rates were chosen: low ventilation (12 L/s) and high ventilation (20 L/s). A significant difference in the dry heat loss at the upper body excluding the head and hands (UBody) was noted among the three sizes (p < 0.05). The ventilation rate significantly increased the total UBody heat loss and thereby reduced UBody's apparent evaporative resistance (p < 0.05). Clothing size showed varied impact on the UBody heat loss and the impact varied with air ventilation rates. Air ventilation could greatly reduce predicted core temperatures, mean skin and UBody temperatures in both sizes small and large . In contrast, clothing size had almost no impact on predicted thermophysiological responses in high ventilation. This work may be useful for designing and improving high-performance air ventilation clothing.
科研通智能强力驱动
Strongly Powered by AbleSci AI