航程(航空)
探测器
物理
核物理学
工程类
光学
航空航天工程
作者
Jiandi Guo,Zhouyu Liu,Qingming He,Danbin Huang,Zi-Wei Lin,Liangzhi Cao,Hongchun Wu
标识
DOI:10.1051/epjconf/202430214001
摘要
This paper analyses the count rate of the ex-core source-range detector for Unit 4, M310 Pressurized Water Reactor (PWR), at Fujian Fuqing Nuclear Power Co., Ltd (FQNPC). The analysis encompasses power states during Cycle 1 startup and Cycle 3 fuel unloading. The analytical process involves analysing the count rate of the source-range detector, simulating secondary neutron source intensity and calculating nuclide information and neutron source intensity of irradiated fuel assemblies, etc. The maximum error between the theoretically calculated and measured count rate of the source-range detector is found to be 8.318%, which confirms the accuracy and validity of the count rate analysis method applied to the ex-core source-range detector for M310.