医学
磁共振弥散成像
白质
磁共振成像
接收机工作特性
原发性进行性失语
核医学
放射科
病理
失智症
内科学
痴呆
疾病
作者
Federica Agosta,Pilar M. Ferraro,Elisa Canu,Massimiliano Copetti,Sebastiano Galantucci,Giuseppe Magnani,Alessandra Marcone,Paola Valsasina,Alessandro Sodero,Gıancarlo Comı,Andrea Falini,Massimo Filippi
出处
期刊:Radiology
[Radiological Society of North America]
日期:2015-03-03
卷期号:276 (1): 219-227
被引量:43
标识
DOI:10.1148/radiol.15141869
摘要
To test a multimodal magnetic resonance (MR) imaging-based approach composed of cortical thickness and white matter (WM) damage metrics to discriminate between variants of primary progressive aphasia (PPA) that are nonfluent and/or agrammatic (NFVPPA) and semantic (SVPPA).This study was approved by the local ethics committees on human studies, and written informed consent from all patients was obtained before their enrollment. T1-weighted and diffusion-tensor (DT) MR images were obtained from 13 NFVPPA patients, 13 SVPPA patients, and 23 healthy control participants. Cortical thickness and DT MR imaging indices from the long-associative and interhemispheric WM tracts were obtained. A random forest (RF) analysis was used to identify the image features associated with each clinical syndrome. Individual patient classification was performed by using receiver operator characteristic curve analysis with cortical thickness, DT MR imaging, and a combination of the two modalities. RESULTS RF analysis showed that the best markers to differentiate the two PPA variants at an individual patient level among cortical thickness and DT MR imaging metrics were diffusivity abnormalities of the left inferior longitudinal and uncinate fasciculi and cortical thickness measures of the left temporal pole and inferior frontal gyrus. A combination of cortical thickness and DT MR imaging measures (the so-called gray-matter-and-WM model) was able to distinguish patients with NFVPPA and SVPPA with the following classification pattern: area under the curve, 0.91; accuracy, 0.89; sensitivity, 0.92; specificity, 0.85. Leave-one-out analysis demonstrated that the gray matter and WM model is more robust than the single MR modality models to distinguish PPA variants (accuracy was 0.86, 0.73, and 0.68 for the gray matter and WM model, the gray matter-only model, and the WM-only model, respectively).A combination of structural and DT MR imaging metrics may provide a quantitative procedure to distinguish NFVPPA and SVPPA patients at an individual patient level. The discrimination accuracies obtained suggest that the gray matter and WM model is potentially relevant for the differential diagnosis of the PPA variants in clinical practice.
科研通智能强力驱动
Strongly Powered by AbleSci AI