Nafion公司
介电谱
电极
循环伏安法
化学
电化学
剥离(纤维)
伏安法
玻璃碳
分析化学(期刊)
碳纳米管
碳纤维
电化学气体传感器
化学工程
纳米技术
材料科学
复合材料
色谱法
复合数
工程类
物理化学
作者
Yueying Zhang,Hao Yu,Tong Liu,Weijia Li,Xidong Hao,Qi Lu,Xishuang Liang,Fengmin Liu,Fangmeng Liu,Chenguang Wang,Chunhua Yang,Hongqiu Zhu,Geyu Lu
标识
DOI:10.1016/j.aca.2020.05.023
摘要
A series of different facile modification layers (MLs) was designed to gradually increase the electrochemical sensing performance of glassy carbon electrode (GCE) for simultaneously detecting Pb2+ and Cu2+. ML designs were mainly a different combination of ZIF-67, MWCNT and Nafion, and their different electrochemical sensing performances were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), square wave stripping voltammetry (SWSV) and chronocoulometry. The fabricated sensor, which modified with ZIF-67/MWCNT and Nafion layer, exhibited the biggest response peak current to Pb2+ and Cu2+. In addition, it displayed a wide linear detection range of 1.38 nM-5 μM for Pb2+ and 1.26 nM-5 μM for Cu2+, a detection accuracy of about 1 nM for both Pb2+ and Cu2+, and an excellent stability for both Pb2+ and Cu2+. We also analyzed the real water sample taken from Changchun's Sanjia Lake and Yan Lake. We believe this ML design provides instruction for building high-performance electrochemical sensing systems.
科研通智能强力驱动
Strongly Powered by AbleSci AI