Left atrial appendage patency and device-related thrombus after percutaneous left atrial appendage occlusion: a computed tomography study

医学 闭塞 血栓 经皮 血栓形成 左心耳阻塞 心房颤动 心脏病学 放射科 内科学 心耳 冲程(发动机) 机械工程 工程类 窦性心律 华法林
作者
Hubert Cochet,Xavier Iriart,Soumaya Sridi,Claudia Camaioni,O. Corneloup,Michel Montaudon,François Laurent,Wieme Selmi,Pauline Renou,Zakaria Jalal,Jean‐Benoît Thambo
出处
期刊:European Journal of Echocardiography [Oxford University Press]
卷期号:19 (12): 1351-1361 被引量:87
标识
DOI:10.1093/ehjci/jey010
摘要

Aims: Transoesophageal echocardiography studies have reported frequent peri-device leaks and device-related thrombi (DRT) after percutaneous left atrial appendage (LAA) occlusion. We assessed the prevalence, characteristics and correlates of leaks and DRT on cardiac computed tomography (CT) after LAA occlusion. Methods and results: Consecutive patients underwent cardiac CT before LAA occlusion to assess left atrial (LA) volume, LAA shape, and landing zone diameter. Follow-up CT was performed after >3 months to assess device implantation criteria, device leaks and DRT. CT findings were related to patient and device characteristics, as well as to outcome during follow-up. One-hundred and seventeen patients (age 74 ± 9, 37% women, CHA2DS2VASc 4.4 ± 1.3, and HASBLED 3.5 ± 1.0) were implanted with Amplatzer cardiac plug (ACP)/Amulet (71%) or Watchman (29%). LAA patency was detected in 44% on arterial phase CT images and 69% on venous phase images. The most common leak location was postero-inferior. LAA patency related to LA dilatation, left ventricular ejection fraction impairment, non-chicken wing LAA shape, large landing zone diameter, incomplete device lobe thrombosis, and disc/lobe misalignment in patients with ACP/Amulet. DRT were detected in 19 (16%), most being laminated and of antero-superior location. DRT did not relate to clinical or imaging characteristics nor to implantation criteria, but to total thrombosis of device lobe. Over a mean 13 months follow-up, stroke/transient ischaemic attack occurred in eight patients, unrelated to DRT or LAA patency. Conclusion: LAA patency on CT is common after LAA occlusion, particularly on venous phase images. Leaks relate to LA/LAA size at baseline, and device malposition and incomplete thrombosis at follow-up. DRT is also quite common but poorly predicted by patient and device-related factors.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
刚刚
1秒前
fufu完成签到,获得积分10
2秒前
隐形曼青的应助被帅子采纳,获得10
2秒前
2秒前
Linjm完成签到 ,获得积分10
2秒前
4秒前
5秒前
5秒前
year完成签到 ,获得积分10
6秒前
震甫完成签到,获得积分10
6秒前
喔吼完成签到,获得积分10
6秒前
俊逸的映易完成签到,获得积分10
6秒前
6秒前
111发布了新的文献求助10
6秒前
7秒前
8秒前
8秒前
8秒前
Nole的应助被大方的笑萍采纳,获得10
9秒前
Smile_Uo完成签到,获得积分10
9秒前
9秒前
咻咻发布了新的文献求助10
10秒前
知行合一完成签到,获得积分10
10秒前
小马发布了新的文献求助10
12秒前
lbh发布了新的文献求助10
12秒前
obtu发布了新的文献求助10
12秒前
yzw发布了新的文献求助10
13秒前
Elaine完成签到,获得积分10
13秒前
木木完成签到 ,获得积分10
13秒前
汉堡包的应助被自由的若之采纳,获得10
13秒前
13秒前
扶摇完成签到 ,获得积分10
13秒前
JinZ发布了新的文献求助10
13秒前
14秒前
15秒前
16秒前
16秒前
ding的应助被zqz采纳,获得10
16秒前
情怀的应助被柳七采纳,获得10
17秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
拉伸高分子熔体中缠结行为的模拟和小角中子散射研究 2000
Agyptische Geschichte der 21.30. Dynastie 510
高分子基功能界面水蒸发材料与应用研究 500
外场增强的水汽发电研究 500
基于结构调控的功能化水诱导发电材料与器件研究 500
基于界面调控的高效湿气发电材料与器件研究 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 计算机科学 工程类 有机化学 化学工程 生物化学 物理 复合材料 内科学 催化作用 光电子学 人工智能 细胞生物学 无机化学 物理化学 数学
热门帖子
关注 科研通微信公众号,转发送积分 8192250
求助须知:如何正确求助?哪些是违规求助? 9578881
关于积分的说明 21862513
捐赠科研通 7791814
什么是DOI,文献DOI怎么找? 3436868
关于科研通互助平台的介绍 2560584
邀请新用户注册赠送积分活动 2483698