联轴节(管道)
声学
零(语言学)
物理
融合
电子工程
工程类
机械工程
语言学
哲学
作者
Qin Tang,Bin Gao,Qiuping Ma,Gaige Ru,Shuwen Xue,Wenze Shi,Fei Luo,Wai Lok Woo
标识
DOI:10.1109/tim.2025.3555696
摘要
Conventional shear horizontal (SH0) guided wave electromagnetic acoustic transducer (EMAT) has been widely used for pipeline detection due to its advantages of nondispersion and simple vibration mode. While echo amplitude can be utilized to detect defects, it presents limitations in discerning between those residing on the surface and those located subsurface. This article proposes a hybrid sensing methodology that integrates SH0 guided wave EMAT with permanent magnetic field perturbation (PMFP) to enhance the accuracy of both defect identification and classification. From a physical coupling perspective, the system shares the same magnetic circuit structure, and the sensing information is received by different receivers. In particular, the significant frequency difference between the PMFP and the EMAT signal can directly suppress mutual electromagnetic interference (EMI). In addition, the homopolar permanent magnet arrays in EMAT provide an inherent “near-zero” magnetic field region that improves the signal-to-noise ratio (SNR) of the PMFP signal. Both simulations and experiments have been undertaken to demonstrate the feasibility of the fusion sensing system. The system has also been validated with high sensitivity in detecting pits, slits, and large corrosion defects in plates and pipes.