重复性
氢氧化物
色谱法
化学
准确度和精密度
滴定法
乙二胺四乙酸
铝
试剂
校准曲线
数学
检出限
无机化学
螯合作用
有机化学
物理化学
统计
作者
Lorenzo Di Meola,Daniela Pasqui,Chiara Tigli,Stephen L. J. Luckham,Silvio Colomba,Marilena Paludi,Maxime Denis,Angelo Palmese,Daniela Stranges,Agnese Marcelli,Alessio Moriconi,Malte Meppen,Carlo Pergola
出处
期刊:Vaccines
[Multidisciplinary Digital Publishing Institute]
日期:2025-01-22
卷期号:13 (2): 105-105
被引量:1
标识
DOI:10.3390/vaccines13020105
摘要
OBJECTIVE: This manuscript describes an innovative, non-destructive, high-throughput method for the quantification of aluminum hydroxide in aluminum-adjuvanted vaccines, eliminating the need of reagents and providing real-time results. The method is based on a spectrophotometric principle, and several model proteins were studied and tested with the aim to simulate the behavior of aluminum-adjuvanted antigens. METHODS: As a proof of concept, the MenB vaccine was used, and the titration of aluminum hydroxide (AH) with ethylenediaminetetraacetic acid (EDTA) was used as an orthogonal reference, as it is one of the current release methods for the content determination of aluminum-hydroxide-adjuvanted vaccine drug products (DPs). The factors influencing the spectrophotometric analysis, such as different plate 96/well containers, variation in the sedimentation of the suspension due to component addition errors during formulation, and batch-to-batch variation were studied to assess the method's robustness. Five concentration levels (ranging from 2.0 to 4.0 mg/mL AH) with two different batches of aluminum hydroxide were each measured with independent preparations performed by three different operators, for a total of four sessions/operator and 20 formulations/session. An in-depth statistical study was carried out with generated data to assess the precision (in terms of intermediate precision and repeatability), accuracy, linearity, and specificity of the method. RESULTS: The novel spectrophotometric method and the official release one (potentiometric) yielded comparable results, demonstrating the potential of this new method as a release test for AH-adjuvanted products. A simple calibration curve enabled the measurement of samples in a 96-well plate in just a few minutes. CONCLUSIONS: We developed a novel method for Aluminum concentration determination in Aluminum-containing pharmaceutical products, like alum-adjuvanted vaccines. This method is fast, completely automatable, and as precise and accurate as already-in-place release methods.
科研通智能强力驱动
Strongly Powered by AbleSci AI