M.N. Mungole,Nidhi Singh,G. N. Mathur
标识
DOI:10.1179/026708301125000302
摘要
AbstractAbstractThe isothermal oxidation behaviour of two phase (α + β) titanium base alloy Ti6Al4V (coupons) has been studied at 1050, 1150, 1250, and 1340 K in O2 gas at atmospheric pressure for 2, 4, 6, 8, and 12 h. Investigations on kinetic behaviour followed by the metallographic examination of oxidised scale morphology was carried out. Thermogravimetric data (weight gain v time) exhibited parabolic behaviour. Below 1250 K, the rate of oxidation substantially decreased after 8 h exposure, however, at 1340 K the oxidation rate was markedly high over the whole 12 h period. Parabolic rate constants were 0.234×10-7, 3.67×10-7, 10.72×10 -7, and 31.17×10-7 kg2 m-4 s-1 at 1050, 1150, 1250, and 1340 K respectively. The effective activation energy of oxidation was 88 kJ mol-1. The instantaneous rate constant k i exhibited a marked deviation from parabolic behaviour at high temperatures e.g. 1150, 1250, and 1340 K, however, k i at lower temperature (1050 K) remained broadly unchanged with time exhibiting no deviation from parabolic behaviour. Metallographic observation of the sample coupons treated at 1340 K revealed an identical oxide scale morphology with increased thickness over the time.