In this study, the optimum charge rate of the working fluid was determined for maximum performance conditions by conducting numerical analyses for various fluids and different mass flow rates in a thermosyphon heat pipe having 1-inch diameter and 1-m length with heater powers of 300 W, 400 W, and 500 W. As thermosyphon type heat pipes are widely used in many industrial applications, the determination of the charge rate of working fluid depending on the type of fluid used for maximum performance conditions, which is the main purpose of the presented study, is crucial for the design process. In order to evaluate the performance of the heat pipe, different thermal loads were analyzed using the computational fluid dynamics method for different working fluids and charge rates. Working fluids selected for the study are water and Al2O3/water and TiO2/water nanofluids. The temperature distribution along the heat pipe was evaluated in terms of performance of the heat pipe, thermal resistance, and total heat transfer. The amount of liquid filled was altered and the variation of performance parameters was observed. Finally, the optimum liquid filling ratio was determined in terms of lower temperature difference and thermal resistance, and higher heat transfer coefficient. It has been concluded that the optimum performance working fluid ratio is 1/3 (33.3%) of the evaporator volume for maximum efficiency conditions regardless of the type of the working fluid used.