医学
烧蚀
内科学
心脏病学
导管
动脉
导管消融
右冠状动脉
冠状动脉
血管痉挛
冠状动脉痉挛
冠状动脉造影
外科
蛛网膜下腔出血
心肌梗塞
作者
Jacob Sam Koruth,Iwanari Kawamura,Eric D. Buck,Richard Brose,Srinivas Rao Dukkipati,William Whang,Mohit K. Turagam,Daniel Ross Musikantow,Marc A. Miller,Vivek Yerrapu Reddy
出处
期刊:Heart Rhythm
[Elsevier BV]
日期:2022-04-28
卷期号:19 (5): S68-S68
被引量:3
标识
DOI:10.1016/j.hrthm.2022.03.714
摘要
Pulsed Field Ablation (PFA) has gained prominence by virtue of its proclivity to preferentially ablate myocardial tissue. Based on its safety, efficacy and efficiency, after regulatory approval of one multielectrode PFA catheter, there has been rapid uptake into clinical practice in various European centers. In addition, multiple other PFA catheters are under investigation. While the overall safety profile of PFA is quite favorable compared to conventional thermal ablation, it is possible that PFA may yet result in unusual complications. Indeed, a recent case of coronary spasm during off-label ablation along the mitral isthmus was recently reported. To study the potential for coronary spasm during focal endo- or epi-cardial PFA in swine ventricles During a series of endocardial and epicardial dose-finding evaluations, 2 kV bipolar/biphasic PFA pulses were delivered using an 8 Fr focal catheter (Farapoint, Boston Scientific). To evaluate vasospasm, we performed coronary angiography (CAG) after purposefully delivering PF in close proximity to epicardial coronary arteries. After sub-xyphoid pericardial access, the catheter was positioned immediately adjacent to the left anterior descending artery (LAD) in one swine. In two other swine, the catheter was positioned endocardially, immediately above the right coronary artery (RCA) at the proximal cavotricuspid isthmus in one swine and in the pulmonary artery trunk near the LAD in the other swine. In the swine with epicardial PFA, immediately after the ablation pulses, ST-elevation in the precordial leads was observed. Repeat CAG revealed spasm along the length of the catheter-tip. The spasm gradually recovered over 50 minutes and the animal was successfully survived. In the other 2 swine with endocardial PFA, no ST-changes were observed for either applications. However, CAG demonstrated coronary spasm of the RCA, but not in the LAD. Resolution of RCA spasm was not documented by repeat CAG. These swine was also successfully survived. Coronary spasm can occur when PFA is performed in close proximity to large epicardial vessels in swine. Further detailed assessments in different animal models are needed to understand its incidence, dependence on proximity and location as well as therapeutic approaches.View Large Image Figure ViewerDownload Hi-res image Download (PPT)
科研通智能强力驱动
Strongly Powered by AbleSci AI