替米沙坦
色谱法
灵敏度(控制系统)
化学
高效液相色谱法
医学
工程类
内科学
电子工程
血压
作者
Muhammad Shahzad Chohan,Mahesh Attimarad,Katharigatta N. Venugopala,Anroop B. Nair,Nagaraja Sreeharsha,Efren II Plaza Molina,Ramling Bhagavantrao Kotnal,Sheeba Shafi,Marysheela David,Pottathil Shinu,Abdulrahman Ibrahim Altaysan,Abdulmalek Ahmed Balgoname
标识
DOI:10.3390/ijerph19127260
摘要
The development of an environmentally friendly analytical technique for simultaneous measurement of medicines with large concentration differences is difficult yet critical for environmental protection. Hence, in this work, new manipulated UV-spectroscopic methods with high scaling factors were established for concurrent quantification of telmisartan (TEL) and benidipine (BEN) in fixed-dose combinations. Two different methods were developed and established by calculation of peak height at zero crossing point of second derivative and the ratio of first derivative spectra with a scaling factor of 200 and 100, respectively. The absorption difference between the peaks and troughs of the ratio spectra, as well as continuous subtraction from ratio spectra, were established as additional methods. In addition, new procedures were validated using ICH recommendations. The proposed methods' linearity curves were constructed in the range of 0.5-10 µg mL-1 and 1-30 µg mL-1 for BEN and TEL, respectively, under optimized conditions. Furthermore, both the detection (0.088-0.139 µg mL-1 for BEN and 0.256-0.288 µg mL-1 for TEL) and quantification limits (0.293-0.465 µg mL-1 for BEN and 0.801-0.962 µg mL-1 for TEL) were adequate for quantifying both analytes in the formulation ratios. The accuracy and precision were confirmed by the good recovery percent (98.37%-100.6%), with low percent relative error (0.67%-1.70%) and less than 2 percent relative standard deviation, respectively. The specificity of the methods was proven by accurate and precise outcomes from the standard addition method and analysis of laboratory mixed solutions with large differences in concentrations of both analytes. Finally, the BEN and TEL content of the formulations was determined simultaneously without prior separation using these first ever reported spectroscopic methods. Furthermore, developed UV derivative spectroscopic methods demonstrated high greenness and whiteness when compared to the reported HPLC methods. These findings show that the projected methods were effective, practical, and environmentally acceptable for quality control of BEN and TEL in multicomponent formulations.
科研通智能强力驱动
Strongly Powered by AbleSci AI