气胸
医学
肺容积
射线照相术
胸腔
体积热力学
胸部(昆虫解剖学)
肺
核医学
外科
解剖
内科学
量子力学
物理
作者
James T. Rhea,S A DeLuca,Reginald E. Greene
出处
期刊:Radiology
[Radiological Society of North America]
日期:1982-09-01
卷期号:144 (4): 733-736
被引量:159
标识
DOI:10.1148/radiology.144.4.7111716
摘要
A simple measurement, the average interpleural distance (AID), which is obtained from three linear measurements, closely predicts true pneumothorax size as determined by radiographic thoracic gas volume measurement (mean variation -2.4 +/- 7.23 SD). The distribution of pneumothorax volume between the affected lung and the ipsilateral thoracic cage is variable and unpredictable. It was found that the average volume of pneumothorax that is accommodated by thoracic cage expansion (8%) is much less than previously reported. This appears to be the result of variable degrees of splinting and chest wall pain associated with pneumothorax.