病毒学
人类免疫缺陷病毒(HIV)
病毒载量
医学
作者
Shawna Lewis,Elizabeth Morehead,Helen Cheung,Heba H. Mostafa
标识
DOI:10.1016/j.diagmicrobio.2023.115951
摘要
The clinical performance of the Aptima® HIV-1 Quant Dx, Aptima HCV Quant Dx, and Aptima HBV Quant Dx were evaluated and compared to the Roche cobas HIV-1, HCV, and HBV assays performed on the Roche cobas 6800 system. The Aptima Quant assays exhibited an overall percent agreement of 99.4% for HBV, 98.3% for HCV, and 85.14% for HIV-1. The average log difference between the Aptima and Roche assays was below 0.2 IU (or copies)/mL and the quantitative correlation's (R-squared value (R2)) was between 0.95 and 0.97. The Aptima viral assays demonstrated a high level of quantitative correlation with the Roche cobas assays for HCV, HBV, and HIV-1.