Background The study objective was to examine the correlation between regional ventilation distribution measured with electrical impedance tomography ( EIT ) and weaning outcomes during spontaneous breathing trial ( SBT ). Methods Fifteen patients received 100% automatic tube compensation ( ATC ) during the first and 70% during the second hour. Another 15 patients received external continuous positive airway pressure ( CPAP ) of 5 and 7.5 cmH 2 O during the first and second hours, respectively. Regional ventilation distributions were monitored with EIT . Results Tidal volume and tidal variation of impedance correlated significantly during assist‐control ventilation and ATC in all patients ( r 2 = 0.80 ± 0.18, P < 0.001). Higher support levels resulted in similar ventilation distribution and tidal volume, but higher end‐expiratory lung impedance ( EELI ) ( P < 0.05). Analysis of regional intratidal gas distribution revealed a redistribution of ventilation towards dorsal regions with lower support level in 13 of 30 patients. These patients had a higher weaning success rate (only 1 of 13 patients failed). Eight of 17 other patient failed ( P < 0.05). The number of SBT days needed for weaning was significantly lower in the former group of 13 patients (13.1 ± 4.0 vs. 20.9 ± 11.2 days, P < 0.05). Conclusions Regional ventilation distribution patterns during inspiration were associated with weaning outcomes, and they may be used to predict the success of extubation.