搪瓷漆
牙釉质
电子顺磁共振
生物剂量学
材料科学
剂量学
再现性
臼齿
核磁共振
辐照
辐射
光学
核医学
化学
牙科
电离辐射
物理
复合材料
医学
核物理学
色谱法
作者
A. Romanyukha,C. A. Mitchell,David A Schauer,Lyudmila Romanyukha,Harold M. Swartz
出处
期刊:Health Physics
[Lippincott Williams & Wilkins]
日期:2007-12-01
卷期号:93 (6): 631-635
被引量:34
标识
DOI:10.1097/01.hp.0000269507.08343.85
摘要
A comparative study of electron paramagnetic resonance dosimetry in Q- and X-bands has shown that Q-band is able to provide accurate measurements of radiation doses even below 0.5 Gy with tooth enamel samples as small as 2 mg. The optimal amount of tooth enamel for dose measurements in Q-band was found to be 4 mg. This is less than 1% of the total amount of tooth enamel in one molar tooth. Such a small amount of tooth enamel can be harmlessly obtained in an emergency requiring after-the-fact radiation dose measurement. The other important advantage of Q-band is full resolution of the radiation-induced EPR signal from the native, background signal. This separation makes dose response measurements much easier in comparison to conventional X-band measurements in which these overlapping signals necessitate special methods for doses below 0.5 Gy. The main disadvantages of Q-band measurements are a higher level of noise and lower spectral reproducibility than in X-band. The effect of these negative factors on the precision of dose measurements in Q-band could probably be reduced by improvement of sample fixation in the resonance cavity and better optimization of signal filtration to reduce high-frequency noise.
科研通智能强力驱动
Strongly Powered by AbleSci AI