In this paper, aluminum alloy was used as the substrate and the laser etching method was used to study the influence of groove geometric parameters and on microfluid flow velocity. The experimental results show that in the case of parallel grooves, when the groove width is constant, the smaller the groove spacing, the greater the flow velocity of fluid. When the depth width ratio of the groove is around 1.5, the fluid flow velocity is the largest. In the case of non-parallel, when the groove angle is close to 0°, the fluid transport speed was the largest. Under the condition of parallel multi-channels, a synergistic effect between the channels has been observed, further promoting the flow of liquid. On the other hand, when the sum of the groove angle and the advancing contact angle of the droplet is 90°, the capillary force moving fluid forward will reach the maximum.