Abstract A simple, sensitive and rapid ultra‐high‐performance liquid chromatography–electrospray ionization–tandem mass spectrometry method was developed and validated for the quantification of warfarin and 7‐hydroxy warfarin in Sprague Dawley (SD) rats. Animals were administered a single dose of warfarin sodium formulations (crystalline and amorphous) at 12 mg/kg via oral gavage and blood was drawn over a 96‐h time course. Sample process recoveries, matrix effect and analyte stability were determined. The linearity for warfarin and 7‐hydroxy warfarin was from 5 to 2000 ng/mL in blank SD rat plasma. Correlation coefficients ( r 2 ) for standard calibration curves were >.98 and analytes quantified within ±15% of target at all calibrator concentrations. The average percent accuracy and precision for intra‐ and inter‐day were 93.7%–113.8% and ≤12.1%, respectively, for warfarin and 7‐hydroxy warfarin, across the quality control standards (5, 10, 500, 1800 and 2000 ng/mL). Acceptable analytical recovery (>55%) was achieved with process efficiencies >41.5% and matrix effects <139.9% over the analytical range. Both analytes were stable in stock solution, autosampler, benchtop and three cycles of freeze–thaw with percent accuracy ≥90.2% and precision (percent relative standard deviation) ≤14%. The validated method was successfully applied to a pre‐clinical bioavailability study of crystalline and amorphous warfarin sodium formulations in SD rats.