Water exchange is superior to air insufflation in reducing discomfort and increasing adenoma detection during colonoscopy. However, prolonged cecal insertion time is a drawback. This study aims to investigate the factors affecting cecal insertion during water exchange colonoscopy.We pooled data from five randomized clinical trials that included patients undergoing water exchange colonoscopy. Logistic analysis was performed to determine the independent factors associated with prolonged cecal insertion time (> 15 min).The cohort included 912 patients (493 men and 419 women) with a median age of 57 years (interquartile range, 49-64 years). The median cecal insertion time was 13.5 min (interquartile range, 10.9-17.0 min). Multivariate logistic regression analysis indicated that female sex, body mass index < 25 kg/m2 , a history of constipation, no sedation, less experienced endoscopist, Boston Bowel Preparation Scale score ≤ 6, infused water volume during insertion ≥ 1000 mL, and scope length at the cecum ≥ 85 cm were associated with prolonged cecal insertion time. With increasing volume of infused water (1000-2000 mL), the median cecal insertion time increased gradually from 11.4 to 23.0 min (P < 0.001).The current study identified independent factors associated with prolonged cecal insertion time during water exchange colonoscopy. Several factors are modifiable to achieve a shorter insertion time, including better bowel preparation, the use of sedation, more experienced endoscopist, infusing less water during insertion, and maintaining a shorter scope length.