摘要
Editor, Infusion of lipid emulsion is now recommended to treat any cardiac or neurological complications after local anaesthetic injection during local–regional anaesthesia.1,2 We report ineffectiveness of lipid administration in a patient with neurological complication after an ultrasound-guided sciatic nerve block. Case report A 51-year-old ASA 2 female patient (height 157 cm, weight 57 kg) presented for left hallux valgus surgery under sciatic nerve block. Six months previously she had undergone an uneventful ultrasound-guided sciatic nerve block with 5 mg ml−1 levobupivacaine (100 mg) performed for the same surgical procedure on the contralateral side. She suffered from a trigeminal neuralgia diagnosed 3 months before and was treated with carbamazepine twice daily (200 mg in the morning and 400 mg in the evening) not interrupted before surgery. A 20-gauge peripheral venous catheter was inserted and 3 l min−1 oxygen was delivered via nasal prongs. No intravenous sedation was used during the block performance. Heart rate (with a three-lead ECG), noninvasive blood pressure and oxygen saturation were monitored continuously during the procedure. Baseline blood pressure, room air oxygen saturation and heart rate were 134/67 mmHg, 99% and 65 beats min−1, respectively. The sciatic nerve was scanned at the popliteal fossa using a linear array transducer (6 and 13 MHz, S-Nerve; SonoSite, Bothell, Washington, USA) with the patient supine with her leg elevated to make it possible to introduce the ultrasound scanner into the back of the thigh. The transverse sonogram achieved a good visualization of the sciatic nerve as a round hyperechoic structure posterior to the popliteal vessels. Tibial and fibular nerves were identified by a cephalic shift of the probe head and the site of puncture was chosen just above the bifurcation of the sciatic nerve. An 80-mm 22-gauge short-bevelled needle (Nanoline, Pajunk, Geisingen, Germany) was inserted towards the sciatic nerve using an in-plane approach without neurostimulation. The needle was advanced carefully to avoid inadvertent popliteal vessel injection. After carefully aspiration, 30 ml of a 50/50 mixture of lidocaine 20 mg ml−1 and ropivacaine 7.5 mg ml−1 solution was slowly injected over approximately 2 min in real-time assessment, with intermittent aspiration. At the end of the injection, the sciatic nerve was completely surrounded by local anaesthetic without nerve swelling. No paresthesia, pain or ECG changes were noted during the procedure. At this time, arterial pressure and heart rate were 134/67 mmHg and 54 beats min−1, respectively, and remained stable. Five minutes later, a saphenous nerve block was performed just above the ankle with 5 ml of lidocaine 20 mg ml−1. Twenty minutes later, a sensory and motor block of the lower limb was noted on the two nerves without any haemodynamic or neurological change. Thirty minutes after the sciatic nerve block injection, the patient became agitated and confused with jerking movements of her arms and head. Arterial pressure was 156/87 mmHg and heart rate ranged between 100 and 110 beats min−1 without arrhythmia or QRS enlargement. Respiratory rate increased without change in oxygen saturation. Local anaesthetic toxicity was highly suspected and 3 mg of midazolam were given with a 100 ml bolus of intralipid 20% emulsion (Fresenius, France). Venous blood was sampled for measurement of the plasma concentration of local anaesthetic. Two minutes later, the patient remained unresponsive with a Glasgow score of 7 and the jerking movements persisted. A second bolus of intralipid was injected (100 ml). No improvement in the neurological status was noted. Orotracheal intubation was performed after thiopental 300 mg and suxamethonium 80 mg administration leading to immediate disappearance of neurological symptoms. ECG did not show rhythm conduction or ST abnormalities and systolic arterial pressure remained within 145–95 mmHg range. Arterial blood gas values (on FiO2 50%) were pO2 214 mmHg, pCO2 43 mmHg, pH 7.39 and base excess 0.5 mmol l−1. Cerebral tomodensitometry was performed and no abnormalities were observed. A lumbar puncture show documented clear sterile cerebrospinal fluid without electrolyte abnormalities. Fifty-five minutes after intubation (90 min after the local anaesthetic injection), the patient awaked and was extubated. Neurological examination was normal. Plasma venous concentrations of lidocaine and ropivacaine (sampled just after the first intralipid bolus) were 2.3 and 0.5 μg ml−1, respectively. The serum concentration of carbamazepine was 7 μg ml−1. Troponine Ic was undetectable, serum glucose was 6.2 mmol l−1 and sodium was 137 mmol l−1. The patient reported anaesthesia on both components of the sciatic nerve on the leg, but surgery was postponed. The patient was discharged the next morning. Three months later, a phone call was made to check that the patient was healthy. Discussion Local anaesthetic toxicity may occur immediately after an inadvertent intravenous injection or after a certain delay related to plasma absorption.3 Compared with neurostimulation, ultrasonography guidance reduces but does put an end to the risk of vascular puncture.4 In the current case report, neurological symptoms occurred 30 min after administration of lidocaine 300 mg (5.2 mg kg−1) and ropivacaine 112.5 mg (1.97 mg kg−1) and were likely due to local anaesthetic absorption. No generalized seizures were noted. Carbamazepine treatment had not been interrupted and plasma concentration of carbamazepine was within the therapeutic range, making it unlikely that neurological symptoms could be related to carbamazepine withdrawal or overdose. However, both agents are voltage-gated sodium channels blockers with a common binding site.5 Carbamazepine and local anaesthetic may have combined their effects to favour the occurrence of neurotoxicity. In addition, carbamazepine has been reported to induce a paradoxical increase in seizure frequency and especially myoclonic seizures and nonmyoclonus shock-like involuntary jerk movements.6 Two boluses of 20% intralipid did not stop jerking movements of the arms. In our case report, the plasma concentration of local anaesthetic, determined after the first intralipid bolus injection, revealed therapeutic ranges of each local anaesthetic, about 30 min after completion of local anaesthetic injection. In a previous case report, plasma concentrations of ropivacaine and lidocaine were 0.872 and 0.648 μg ml−1, respectively, at the time of cardiac arrhythmia, 15 min after lumbar plexus blockade was performed with 20 ml of an equal mixture of lidocaine 10 mg ml−1, epinephrine and ropivacaine 7.5 mg ml−1.3 Successful reversion of cardiac toxicity was noted with a single injection of intralipid 20% after lumbar plexus block.3 By contrast, when haemodynamics are compromised, continuous infusion is recommended to reverse cardiac toxicity, which occurs most often after an accidental intravascular injection, with a rapid, high plasmatic peak.1,7 We speculated that lipid administration was poorly effective in reducing lidocaine concentration because lidocaine is less lipid soluble than ropivacaine. Capture of lidocaine by intralipid was therefore likely to be less effective than could be for bupivacaine or ropivacaine, explaining the lack of efficacy of lipid emulsion in this case. The use of lipid emulsion in case of lidocaine toxicity could therefore be ineffective and administration should be recommended only when a lipid-soluble local anaesthetic has been injected. This would explain the ineffectiveness of lipid emulsion in treating acute systemic toxicity with lidocaine. Finally, our case report is of an incident occurring during ultrasound-guided block – the entire procedure of sciatic nerve block was uneventful, respecting the ultrasound guidelines for peripheral nerve block. The doses used for both local anaesthetics were in accordance with the maximum dose authorized for a single-shot injection. The use of ultrasound increases anaesthesia quality in block performance with a lower local anaesthetic dose when compared with neurostimulation,4 but we should remember that toxicity might have occurred even with a high-quality ultrasound nerve block procedure and reduced local anaesthetic dose. Carbamazepine treatment may interfere with clinical presentation of neurological disorder and this has to be taken into account.