电化学发光
注意事项
检出限
检测点注意事项
微流控
化学
心肌梗塞
纳米技术
内科学
色谱法
材料科学
心脏病学
病理
医学
作者
Lihang Zhu,Wenxuan Fu,Boyu Zhu,Feng Qian,Xudong Ying,Shuang Li,Jing Chen,Xiaoya Xie,Chenying Pan,Jun Liu,Chao Chen,Xing Chen,Danhua Zhu
出处
期刊:Talanta
[Elsevier BV]
日期:2023-05-05
卷期号:262: 124626-124626
被引量:15
标识
DOI:10.1016/j.talanta.2023.124626
摘要
Heart-type fatty acid binding protein (H-FABP) is an early biomarker for acute myocardial infarction. The concentration of H-FABP in circulation sharply increases during myocardial injury. Therefore, fast and accurate detection of H-FABP is of vital significance. In this study, we developed an electrochemiluminescence device integrated with microfluidic chip (designed as m-ECL device) for on-site detection of H-FABP. The m-ECL device is consisted of a microfluidic chip that enable easy liquid handling as well as an integrated electronic system for voltage supply and photon detection. A sandwich-type ECL immunoassay strategy was employed for H-FABP detection by using Ru (bpy)32+ loaded mesoporous silica nanoparticles as ECL probes. This device can directly detect H-FABP in human serum without any pre-treatment, with a wide linear range of 1-100 ng/mL and a low limit of detection of 0.72 ng/mL. The clinical usability of this device was evaluated using clinical serum samples from patients. The results obtained from m-ECL device are well matched with those obtained from ELISA assays. We believe this m-ECL device has extensive application prospects for point-of-care testing of acute myocardial infarction.