摘要
Mark Nicholls speaks to medical device expert Prof. John Rogers about how soft electronics are being applied to cardiac tools and heart monitoring. An advanced class of medical instruments based upon traditional balloon catheter systems and carrying a range of soft electronics and sensors are poised to deliver a new dimension to cardiac interventions and therapies. Biomedical engineers at Northwestern University in Chicago and the George Washington University in Washington, DC, have applied stretchable and flexible matrices of electrode sensors and actuators to balloon catheter systems to create flexible tools that move with the beating heart. The aim is to streamline cardiac interventions—such as making ablations to treat arrhythmias quicker, safer, and more patient-friendly—as well as simultaneously gathering imagery and critical electrophysical data such as temperature while delivering real-time feedback. The research team says that by using softer materials, the system offers advantages over rigid traditional catheters. John Rogers, the Louis Simpson and Kimberly Querrey Professor of Materials Science and Engineering, Biomedical Engineering and Neurological Surgery at Northwestern University, said the new tools could have significant benefits in terms of cardiac procedures, such as with ablation. Currently conducted with rigid catheters inserted into the endocardial space to identify tissue causing the abnormal heart rhythm, followed by a second catheter to perform the ablation procedure, he said the single-point catheters that do the mapping and ablation in a point-by-point sequential manner require high skill levels to move catheters around in a beating heart. ‘Our idea was to leverage our capabilities in soft electronics and instrument a balloon with sensors and ablation electrodes’, he explained. ‘The aim was to put a deflated balloon into the inner chambers of the heart, and inflate to softly press a multiplex array of sensors and ablation electrodes onto the surface of the heart in such a way that a cardiologist can map and ablate in one shot’. The soft instrument system, which has been successfully tested in pig models, moves with the heart as it beats while electrodes capture and image the electrical activity, allowing physicians to acquire enough electrophysiological information to complete procedures more quickly with a single instrumented catheter system fitted with advanced organ conformal electronic components, which overcomes the limitations of current systems. The device’s multi-layered, multifunctional, architecture combines diagnostic and therapeutic functions, including irreversible electroporation ablation and delivers drugs and other biomaterials directly into cells. Prof. Rogers said: ‘Hard, rigid catheters cannot conform to the heart because the heart itself is not hard and rigid. We leveraged our advances in soft, stretchable and flexible electronics to develop medical devices that include elastic, interconnected arrays of sensors and actuators, capable of gently and softly conforming to tissue surfaces. The result improves the accuracy and precision of associated surgical processes, for faster, less risky and more effective treatments’. Central to the new class of medical instruments is the ability of the biocompatible electronics to extract high-quality, multi-modal, multi-nodal, continuous data that physicians can act upon. Human trials are expected within 5 years, or sooner, following the successful animal model trials but as an engineer, Prof. Rogers remains cautious on timescale, though acknowledges that physicians are better placed to judge when to apply such technologies to their critically ill patients. In a further project, research is focusing on bioresorbable wireless pacemakers inserted after cardiac procedures that naturally dissolve and resorb into the body after they are no longer needed. Advanced medical instruments on traditional balloon catheter systems (deflated and inflated) with soft electronics and sensors for cardiac interventions and therapies. ‘The ability to do that with a device that does not require a secondary surgical extraction can be very valuable’, he said.2 Alongside innovative cardiac surgical tools, biomedical engineers at Northwestern University have a growing reputation in developing smaller, softer, more accurate, wireless, and battery-free skin interface devices for continuous monitoring of blood flow, blood pressure, blood oxygenation, temperature, and heartbeat in patients. A small device on the chest and another on the hand or foot—even in babies—can measure circulatory behaviour, differences in temperature between the core and periphery of the body, blood oxygenation, and other parameters associated with haemodynamics. Further images show small, flexible, band-aid style devices for continuous monitoring of blood flow, blood pressure, temperature, and heartbeat in patients (image source: Northwestern University). ‘With a device on the chest and on the hand or foot running simultaneously’, explained Prof. Rogers, ‘we can measure differences in temperature between the core and periphery; blood oxygenation from that peripheral location; heart rate and heart rate variability; and determine certain parameters associated with haemodynamics, which can lead to insights into systolic and diastolic blood pressure for example. With all data continuous streaming in a wireless way, devices capture electrical and mechanical activity’. Devices that sit on the skin are minimally invasive platforms of electronics in the style of a band-aid strip and contain an array of photodetectors and light-emitting diodes, to monitor patient data. Smartphones can be used as monitors, and upload data to the cloud. A particular emphasis is on working with vulnerable patients at both ends of the spectrum: in neonatal paediatric health and elderly patients. Neonates, he said, are a major challenge because of the sensitivity of the skin, and small limbs and muscles, and that has led development of their most sophisticated and sensitive platforms. The band-aid style devices, for 24/7 care of neonates, applied to relevant parts of the anatomy are battery-free and use wireless power and data transfer, dispensing of the ‘primitive and constraining technology’ of cables to allow critical skin-to-skin contact to continue between mother and child. With high mortality during childbirth in LMICs (Low and Middle Income Countries) these devices, piloted in Chicago hospitals, have been successfully applied in resource-limited countries such as Zambia, Ghana, and Kenya, with wireless devices measuring the cardiac health of the mother, foetus, and of the neonate during and immediately after birth. Prof. Rogers, who has a research focus on nano and molecular scale fabrication, characteristics of soft materials, bio-inspired and bio-integrated technologies, said cardiac monitoring devices and innovative tools are an important area of interest to the group, which collaborates with interventional cardiologists. He remains acutely aware of the importance of softer materials in maintaining patient compliance. The skin-based devices use silicon and related compound semiconductors to support the electronics, structured in open mesh architectures embedded in soft silicone elastomers. This combines the rigid materials with soft flexible materials in a hybrid formation, paving the way for cost-effective manufacturing and devices that are more compatible for the skin. ‘If a device creates any irritation or discomfort at the skin interfaces, most patients will not use it. You can develop a fantastic device with spectacular measurement capabilities but it is meaningless if patients are unable or unwilling to use it’. With engineering activities based at a main campus at Evanston, plus labs in the major medical complexes of Chicago, the unit has ongoing trials of devices for cardiology, neurology, neonatology, paediatrics, nephrology, and dermatology. Patients with heart failure, cardiomyopathy, coronary artery disease, and stroke survivors are benefitting from this type of monitoring. Conflict of interest: none declared.