医学
结肠镜检查
息肉切除术
内窥镜检查
内窥镜
增生性息肉
腺瘤性息肉
大肠息肉
医学诊断
放射科
指南
诊断准确性
外科
内科学
结直肠癌
病理
癌症
作者
Guido Schachschal,Michael Mayr,András Treszl,K. Balzer,Karl Wegscheider,Jens Aschenbeck,A Aminalai,R Drossel,Andreas Schröder,Mathias Scheel,Carl-Hermann Bothe,Jens-Peter Bruhn,Wolfgang Burmeister,G Stange,Christina Bähr,Ralf Kießlich,Thomas Rösch
出处
期刊:Gut
[BMJ]
日期:2013-06-28
卷期号:63 (3): 458-465
被引量:69
标识
DOI:10.1136/gutjnl-2013-304562
摘要
Background
As screening colonoscopy becomes more widespread, the costs for histopathological assessment of resected polyps are rising correspondingly. Reference centres have published highly accurate results for endoscopic polyp classification. Therefore, it has been proposed that, for smaller polyps, the differential diagnosis that guides follow-up recommendations could be based on endoscopy alone. Objective
The aim was to prospectively assess whether the high accuracy for endoscopic polyp diagnosis as reported by reference centres can be reproduced in routine screening colonoscopy. Design
Ten experienced private practice endoscopists had initial training in pit patterns. Then they assessed all polyps detected during 1069 screening colonoscopies. Patients (46% men; mean age 63 years) were randomly assigned to colonoscopy with conventional or latest generation HDTV instruments. The main outcome measure was diagnostic accuracy of in vivo polyp assessment (adenomatous vs hyperplastic). Secondary outcome measures were differences between endoscopes and reliability of image-based follow-up recommendations; a blinded post hoc analysis of polyp photographs was also performed. Results
675 polyps were assessed (461 adenomatous, 214 hyperplastic). Accuracy, sensitivity and specificity of in vivo diagnoses were 76.6%, 78.1% and 73.4%; size of adenomas and endoscope withdrawal time significantly influenced accuracy. Image-based recommendations for post-polypectomy surveillance were correct in only 69.5% of cases. Post hoc analysis of polyp photographs did not improve accuracy. Conclusions
In everyday practice, endoscopic classification of polyp type is not accurate enough to abandon histopathological assessment and use of latest generation colonoscopes does not improve this. Image-based surveillance recommendations after polypectomy would consequently not meet guideline requirements. TrialRegNo
NCT01297712.
科研通智能强力驱动
Strongly Powered by AbleSci AI