The subbandgap absorption spectroscopy can provide an indication of semiconductor quality already by looking at depth and steepness of the absorption edge. The differences in traditional measurement techniques: Photothermal Deflection Spectroscopy, Constant Photocurrent Method and recently introduced Fourier-Transform Photocurrent Spectroscopy will be discussed, including the frequency dependence issue and sensitivity to surface defects. The mathematical methods of absolute evaluation of absorption coefficient and defect density will be presented. The question of differences in photocurrent measurement of a single absorber layer on glass and of a finished cell will be addressed including the effect of optical scattering and the effect of surface states. Apart from amorphous silicon, recent results obtained on transparent conductive oxides, methyl-ammonium lead triiodide perovskites and cadmium telluride will be discussed.