Yongjian Wu,Xin Sun,Junjie Fan,Shicheng CUI,Huang Wei
摘要
With the increasing function density of space optical remote sensor, the integration of visible and infrared space camera has become an important development direction. As the main vibration, the micro-vibration of refrigerator is the key to affect the imaging quality of optical remote sensor. In this paper, three commonly used micro-vibration test methods are compared, and the fixed-support force test method is used to test and analyze the micro-vibration performance of a pulse tube refrigerator under different power and use state. It is pointed out that the strategy of using compressor vibration isolation to mount satellite is more suitable for the Visible and infrared integrated space camera.