P7. Effect of cage position and insertion angle in the oblique lumbar interbody fusion: A finite element study

笼子 医学 背景(考古学) 腰椎 脊柱融合术 有限元法 口腔正畸科 松质骨 外科 结构工程 地质学 工程类 古生物学
作者
Jung-Woo Hur
出处
期刊:The Spine Journal [Elsevier BV]
卷期号:21 (9): S143-S143 被引量:1
标识
DOI:10.1016/j.spinee.2021.05.215
摘要

BACKGROUND CONTEXT Oblique lateral interbody fusion (OLIF) is considered a useful surgical option for various lumbar degenerative diseases with favorable clinical results and few complications. However, retroperitoneal prepsoas approach compels cage to be inserted more obliquely compared to direct lateral transpsoas approach, where cage is inserted more vertically. Moreover, the effect of cage insertion angle on postoperative cage stability and subsidence has not been fully understood yet. PURPOSE The purpose of the present study was to evaluate the biomechanical effect of cage position and insertion angle on postoperative stability and subsidence following oblique lateral interbody fusion using finite element (FE) model. STUDY DESIGN/SETTING Finite element study. PATIENT SAMPLE Previously validated 3-dimensional FE model of intact lumbar spine (L4-5) was used. OUTCOME MEASURES The cage and pedicle screw – vertebral body interface behavior were assigned ‘tie’ contact condition to simulate complete postoperative bone union. In addition, the likelihood of yield of cage and the risk of the subsidence were compared and analyzed using Peak von Mises Stresses (PVMS) values occurring in each type of cage and cancellous bone, respectively. METHODS For the vertebral fusion procedures, PEEK (E=3500MPa, v=0.3) cage (L40*W22*H12*A12, GS Medical Co., Ltd., Korea) with titanium (E=110000MPa, v=0.33) pedicle screws (Ø6.5 x 45 mm, GS Medical Co., Ltd., Korea) were used. Six surgical models were created according to cage positioning and insertion angles (Type A: anterior 1/3, Type B: center, Type C: posterior 1/3, Type D: anterior 25°, Type E: Center 25°, Type F: Posterior 25°) 10Nm pure moment of flexion/extension, lateral bending and axial rotation was applied at the superior surface of L4 endplate with a compressive follower load of 400N. RESULTS All six models showed lower stress values as compared to the yield strength of PEEK (75Mpa). The 0° models demonstrated (Types A, B and C) significantly lower likelihood of cage yield compared to 25° models (Type D, E and F; 33%, 33% and 30% vs 49%, 47% and 33%, respectively), suggesting anteriorly positioned cage with less insertion angle is more stable. Similarly, in investigating the risk of subsidence, the stresses recorded in the cancellous bone for all six models were less than the reported yield strength of the cancellous bone (16.3Mpa). The 0° models demonstrated (Types A, B and C) significantly lower risk of subsidence compared to 25° models (40%, 57% and 40% vs 68%, 54% and 67.6%, respectively), suggesting anterior or posterior positioned cage with less insertion angle lowers the risk of subsidence. CONCLUSIONS Our study demonstrated that during OLIF, insertion of cage more anteriorly with less insertion angle provided better stability and less chance of subsidence. This study suggests that cage should be inserted more anteriorly and vertically during OLIF procedure to maintain postoperative stability and to reduce cage subsidence. FDA DEVICE/DRUG STATUS This abstract does not discuss or include any applicable devices or drugs. Oblique lateral interbody fusion (OLIF) is considered a useful surgical option for various lumbar degenerative diseases with favorable clinical results and few complications. However, retroperitoneal prepsoas approach compels cage to be inserted more obliquely compared to direct lateral transpsoas approach, where cage is inserted more vertically. Moreover, the effect of cage insertion angle on postoperative cage stability and subsidence has not been fully understood yet. The purpose of the present study was to evaluate the biomechanical effect of cage position and insertion angle on postoperative stability and subsidence following oblique lateral interbody fusion using finite element (FE) model. Finite element study. Previously validated 3-dimensional FE model of intact lumbar spine (L4-5) was used. The cage and pedicle screw – vertebral body interface behavior were assigned ‘tie’ contact condition to simulate complete postoperative bone union. In addition, the likelihood of yield of cage and the risk of the subsidence were compared and analyzed using Peak von Mises Stresses (PVMS) values occurring in each type of cage and cancellous bone, respectively. For the vertebral fusion procedures, PEEK (E=3500MPa, v=0.3) cage (L40*W22*H12*A12, GS Medical Co., Ltd., Korea) with titanium (E=110000MPa, v=0.33) pedicle screws (Ø6.5 x 45 mm, GS Medical Co., Ltd., Korea) were used. Six surgical models were created according to cage positioning and insertion angles (Type A: anterior 1/3, Type B: center, Type C: posterior 1/3, Type D: anterior 25°, Type E: Center 25°, Type F: Posterior 25°) 10Nm pure moment of flexion/extension, lateral bending and axial rotation was applied at the superior surface of L4 endplate with a compressive follower load of 400N. All six models showed lower stress values as compared to the yield strength of PEEK (75Mpa). The 0° models demonstrated (Types A, B and C) significantly lower likelihood of cage yield compared to 25° models (Type D, E and F; 33%, 33% and 30% vs 49%, 47% and 33%, respectively), suggesting anteriorly positioned cage with less insertion angle is more stable. Similarly, in investigating the risk of subsidence, the stresses recorded in the cancellous bone for all six models were less than the reported yield strength of the cancellous bone (16.3Mpa). The 0° models demonstrated (Types A, B and C) significantly lower risk of subsidence compared to 25° models (40%, 57% and 40% vs 68%, 54% and 67.6%, respectively), suggesting anterior or posterior positioned cage with less insertion angle lowers the risk of subsidence. Our study demonstrated that during OLIF, insertion of cage more anteriorly with less insertion angle provided better stability and less chance of subsidence. This study suggests that cage should be inserted more anteriorly and vertically during OLIF procedure to maintain postoperative stability and to reduce cage subsidence.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
Hello的应助被afanda采纳,获得30
刚刚
oleskarabach发布了新的文献求助30
刚刚
Nabya完成签到,获得积分10
刚刚
1秒前
aajhajkahna的应助被00hello00采纳,获得10
4秒前
情怀的应助被机智的幻梦采纳,获得10
4秒前
5秒前
晚风完成签到,获得积分10
6秒前
晚月恋冬发布了新的文献求助10
8秒前
高小姐发布了新的文献求助10
8秒前
Han完成签到 ,获得积分10
9秒前
soga发布了新的文献求助10
10秒前
11秒前
11秒前
11秒前
11秒前
笨笨沛文完成签到,获得积分10
12秒前
向日葵完成签到 ,获得积分10
13秒前
在水一方的应助被饼盖之交采纳,获得10
15秒前
XXY发布了新的文献求助10
16秒前
16秒前
16秒前
16秒前
南平完成签到 ,获得积分10
17秒前
亮亮发布了新的文献求助10
17秒前
17秒前
control完成签到,获得积分10
18秒前
福尔摩琪完成签到 ,获得积分10
18秒前
秀丽的斓完成签到,获得积分10
19秒前
infinity完成签到 ,获得积分10
19秒前
璃桦完成签到 ,获得积分10
21秒前
CIAO完成签到,获得积分10
23秒前
高小姐发布了新的文献求助10
25秒前
17完成签到,获得积分10
27秒前
27秒前
喜悦如萱完成签到,获得积分10
29秒前
XXY完成签到,获得积分10
30秒前
威武苑睐发布了新的文献求助10
31秒前
leec完成签到,获得积分10
31秒前
32秒前
高分求助中
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Les Mantodea De Guyane 2000
Energie-Contracting 1500
Stochastic Models in Operations Research,Vol. 2 600
Organizational Behavior 510
Critical Bildung: Hegel and the Logic of Diremption 500
Stell & Maran's Head and Neck Surgery and Oncology 500
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 计算机科学 工程类 有机化学 化学工程 生物化学 物理 复合材料 内科学 催化作用 光电子学 人工智能 细胞生物学 无机化学 物理化学 数学
热门帖子
关注 科研通微信公众号,转发送积分 8032593
求助须知:如何正确求助?哪些是违规求助? 9470804
关于积分的说明 21246041
捐赠科研通 7602250
什么是DOI,文献DOI怎么找? 3389095
关于科研通互助平台的介绍 2521258
邀请新用户注册赠送积分活动 2426174