无线电技术
乳腺癌
医学
超声波
磁共振成像
放射科
乳腺超声检查
预测建模
乳房磁振造影
支持向量机
癌症
新辅助治疗
乳房成像
构造(python库)
人工智能
交叉验证
集合(抽象数据类型)
接收机工作特性
训练集
乳腺摄影术
双雷达
医学物理学
数据集
机器学习
诊断准确性
作者
Rushuang Mao,Hongxin Zheng,Xiaofeng Tang,Liang Yang,Y X Zhang,Jianhua Zhou
出处
期刊:
[Springer Science+Business Media]
日期:2026-04-14
卷期号:5 (1): 28-
被引量:2
标识
DOI:10.1007/s44178-026-00243-2
摘要
Background Preoperative distinguish between luminal and non-luminal cancers is crucial for treatment decisions making in patients with breast cancers, as neoadjuvant treatment is recommended for non-luminal tumors instead of luminal tumors. Nevertheless, existing methods have several limitations and there is no effective non-invasive approach to predict molecular subtypes of breast cancer. Purpose To construct and validate an radiomics model based on ultrasound and dynamic contrast enhanced magnetic resonance imaging (DCE MRI) for preoperative non-invasive prediction of breast cancer molecular subtypes. Methods A total of 655 breast cancer patients from two centers were retrospectively collected, with 551 patients from center 1 allocated in a 3:1 ratio into a training set (n = 413) and an internal testing set (n = 138), and 104 cases from center 2 serving as an independent external validation set. Eight machine learning algorithms were employed to construct ultrasound radiomics model (R US), MRI radiomics model (R MRI), and combined model (R MRI+US) based on both ultrasound and MR images. The models were tested on the internal testing set, and the algorithm with the best predictive performance was selected for further model performance validation on the external validation set. Results The R MRI+US constructed by support vector machine showed the best predictive performance, with AUC of 0.973 (95%CI: 0.958, 0.988) and 0.872 (95%CI: 0.805, 0.939) in the training and internal testing sets, respectively, significantly higher than those of the R US and R MRI (all P < 0.05). The AUC of the R MRI+US was 0.835 (95%CI: 0.750, 0.921) in the external validation set outperformed single-modality radiomics models (R US, 0.684 [95%CI: 0.560, 0.808], P = 0.066; R MRI, 0.740 [95%CI: 0.620, 0.860], P = 0.113), although there was no significant statistical difference. Conclusion The radiomics combined model based on pretherapeutic ultrasound and DCE MRI demonstrates potential value for differentiating luminal and non-luminal breast cancers, and may serve as a complementary tool to support clinical decision-making.
科研通智能强力驱动
Strongly Powered by AbleSci AI