材料科学
铬酸盐转化膜
腐蚀
冶金
阴极保护
合金
转化膜
锌
电化学
电偶阳极
电极
化学
物理化学
作者
R. Fratesi,G. Roventi,C. Branca,S. Simoncini
标识
DOI:10.1016/s0257-8972(05)80013-1
摘要
The corrosion behaviour of commercial zinc and Zn-Co alloy coatings, with and without chromate conversion treatment, was studied by means of salt spray tests and electrochemical tests in aerated 0.6 M NaCl solution at various pH values. At almost neutral pH values, the chromated Zn-Co coatings show a better corrosion resistance than that for conventional chromated zinc coatings, as a result of a particularly protective chromate conversion layer which increases both the cathodic and anodic overvoltages. At lower pH values, the corrosion resistance of both chromated zinc and chromated Zn-Co alloy decreases. This is attributed to the depolarization of the cathodic reaction (hydrogen reduction) and to the quick destruction of the chromate layer.
科研通智能强力驱动
Strongly Powered by AbleSci AI